Controller - 1 x 1000 W output with
dimming - All loads
CONTENTS
1. USE
This device is a power unit used for managing lighting loads.
The load(s) can be controlled locally either manually or by SCS
commands associated with it (them). They can also be controlled
automatically by digital detectors.
The use of SCS commands and digital detectors requires an SCS
power supply and an addressing module* to be wired on the
BUS.
* The addressing module is not necessary if the installation is
equipped with the software packs.
2. TECHNICAL FEATURES
CONTENTS Page
1. Use ............................1
2. Technical features ................1
3. Overall dimensions................2
4. Connection ......................2
5. Parameter setting .................3
6. Operation .......................3
7. Maintenance.....................3
8. Standards .......................3
230 V~ 1000 W
4.3 A
1000 W
4.3 A
1000 VA
4.3 A
1000 VA
4.3 A
110 V~ 500 W 500 W 500 VA 500 VA
1 2 3 4
1
Incandescent bulbs
2 Tungsten halogen bulbs
3 Tungsten halogen bulbs with ferromagnetic transformer
4 Tungsten halogen bulbs with separate electronic transformer
Number of supply terminal blocks 1
Number of load terminal blocks 1
Connection terminals
Terminal types screw
Terminal capacity 2 x 2.5 mm
2
Number of RJ 45 1
Mains voltage 100-240 V~
Frequency 50/60 Hz
Location category Internal
Degree of protection
Penetration by solid
and liquid matter
IP20
(installation in an enclosure)
Impact resistance IK04
Number of modules 6
Usage temperature -5°C to +45°C
Storage temperature -20°C to +70°C
No load power consumption 0.3 W
Weight 327 g
2. TECHNICAL FEATURES (continued)
LEARN indicator:
indicates the teach
phase or RESET
Indicator
(on if output
activated)
Configurator
Control
button
LEARN button
SCS BUS connection
(RJ 45)
CAUTION:
Do not combine on
the same channel
3
+
4
Only one transformer for use with an electronic switch must be used.