SINUS EVO
1 – 3 kVA
USER MANUAL

Questions and Answers

  • M
    Monica DavisAug 4, 2025
    How to fix LEGRAND Inform SINUS EVO when battery backup time is short?
    • S
      Shelby MurrayAug 4, 2025
      If the battery backup time of your LEGRAND UPS is shorter than expected: * The batteries may not be fully charged. Charge them for at least 5 hours and then check the capacity. * The batteries might be defective.
  • K
    Kimberly GonzalezAug 10, 2025
    Why is the LEGRAND Inform SINUS EVO UPS beeping and overloaded?
    • R
      Robert GomezAug 11, 2025
      The LEGRAND UPS may be beeping twice every second because it's overloaded. This could be due to excess loads on the UPS output, or the UPS might be locked in Bypass mode after repetitive overloads, feeding connected devices directly from the mains. To resolve this, remove excess loads from the UPS output. If it's in Bypass mode, remove excess loads first, then shut down and restart the UPS.
  • E
    Erin Bailey DDSAug 16, 2025
    What to do if LEGRAND Inform SINUS EVO UPS shows fault code 43?
    • T
      Trevor CochranAug 16, 2025
      If your LEGRAND UPS displays fault code 43, it means the UPS shut down automatically because of an overload at the output. To fix this, remove some of the connected devices to reduce the load and then restart the UPS.
  • K
    Kristina WhiteAug 22, 2025
    What to do if LEGRAND UPS shows fault code 14?
    • H
      Hailey TurnerAug 22, 2025
      If your LEGRAND UPS is showing fault code 14, it indicates that a short circuit has occurred at the UPS output. Check the output wiring and any connected devices to see if they are causing a short circuit.
  • R
    Ricky PittmanAug 29, 2025
    What to do if LEGRAND Inform SINUS EVO UPS has no indication even though the mains is normal?
    • M
      Maria WiseAug 29, 2025
      If your LEGRAND UPS shows no indication or alarm even when the mains power is normal: * Check that the AC input power cord is firmly connected to the mains. * Ensure the AC input power cord is correctly plugged into the AC input and not the UPS output.

Summary

WARRANTY

SAFETY

INSTALLATION

DISPLAY

Button Operation

Explains the functions of each button (ON/Mute, OFF/Enter, Select) on the UPS front panel.

LCD Panel

Details the layout and information displayed on the UPS LCD panel, including voltage, load, and mode indicators.

UPS Setting

Explains how to set up the UPS using three programmable parameters for various functions.

Output Voltage Setting

Details how to set the output voltage for different UPS models and voltage ranges.

Operating Mode Description

Explains the different operating modes (Online, ECO, Battery, Bypass, Standby) of the UPS.

Fault Code Table

Lists fault codes, their corresponding events, and icons for troubleshooting.

Warning Indicator

Details various warning indicators, their icons, and associated alarms for user awareness.

TROUBLESHOOTING

Technical Specifications

LEGRAND Inform SINUS EVO Specifications

General IconGeneral
Input Voltage230 V
Output Voltage230 V
Input Frequency50/60 Hz
Number of Outputs4
Communication PortsUSB
Form FactorTower
Operating Temperature0-40 °C
Storage Temperature-15-45 °C
Humidity0-95% non-condensing
TechnologyLine-interactive
Output Frequency50/60 Hz