LEGRAND Niky 800 Specifications

General IconGeneral
Apparent Power800 VA
Active Power480 W
TechnologyLine Interactive
Input Voltage230 V
Output Voltage230 V
Communication PortsUSB
Form FactorTower
Frequency50/60 Hz
WaveformSimulated Sinewave
Input Voltage Range170-280 V
Input Frequency Range45-65 Hz
Operating Temperature0-40 °C
Storage Temperature-15-45 °C
Humidity0-95% non-condensing
Battery TypeSealed Lead Acid
Outlets4
Typical Backup Time at Half Load8 min

Summary

Introduction

Conditions of Use

Installation

Caution: Outlet Wiring Length

Ensure outlet wiring from UPS to utility does not exceed 10 metres.

Notice: Power Plug Disconnection

Avoid disconnecting the 230V power plug during operation to maintain earthing protection.

Warning: Radio Interference

This C2 UPS product may cause residential radio interference; additional measures may be needed.

Signals and Controls

LED Light Signals

Describes meanings of front panel LED colors and flashing patterns.

Audible Signals

Explains the UPS's audible alerts for running status, autonomy, and faults.

Overload and Self-Shutdown

Features

Self Test

Automatic self test executed on switch-on for reliable operation.

Battery Protection

Features automatic battery testing and deep discharge protection.

DC Start Capability

Allows the UPS to be switched on in DC mode (battery operation).

UPS Power Supplied Outlets

Line interactive UPS with AVR for stabilized output voltage during mains fluctuations.

Electrical Protection

Automatic switch-off in case of short circuit.

CPU Microprocessor Control

Microprocessor control for battery life saving shutdown under no load.

EMI/RFI Filtering

Dedicated filter to eliminate electromagnetic radio frequency interferences.

Full Time Surge Protection Outlet

Outlet for appliances not needing backup protection, with surge protection.

Changing Batteries

Caution: Battery Handling

Handle batteries with care to avoid explosion; keep away from children.

Notice: Battery Replacement

Batteries must be replaced by qualified personnel and disposed of according to law.

Possible Malfunctioning

Technical Features

Status LEDs

Identifies the location and meaning of the unit's status indicator LEDs.

Power Switch

Locates the main power switch on the UPS unit.

Telephone, Fax, Modem or Network Protection

Details the RJ11/RJ45 ports for surge protection of communication lines.

Output Sockets

Shows the location of the UPS output power sockets for connected devices.

AC Input with AC Fuse

Identifies the AC power input connector and integrated fuse.

USB Serial Interface

Locates the USB port for connection to a computer for monitoring and control.