Group 7 Data/Programming Page 140
Release R2.0 LEIBINGER JET3
7.3.2 Password settings and user authorizations
The LEIBINGER JET3 offers different access levels which are protected by passwords
from faulty operation or non-authorized access. Five levels of access authorization
are available. For each level any functions can be enabled or blocked to apply access
rights for e.g. operator or supervisor (free definable).
7.3.2.1 Menu password settings
With the option <Password Settings> (2) the menu „Password settings“ (3) opens.
This menu provides
Selection of user levels (Level of access right)
Definition of access rights.
Definition of passwords
In the several tabs you can enable or lock the functions in the current access levels.
An enabled function is displayed by a in the accordant checkbox.
The selection of a tab happens by clicking on the accordant tab (4).
Note: The proceeding corresponds to the Windows™-standard procedure.
With the drop-down list <Level> (5) you can select the user levels for which you
would like to carry out the settings.
In the input field <Password> (6) you can enter the password for the current user
level or you can display an already defined password.
With the button <set…> (7) the password which has been entered for the current
access level will be taken over.
With the button <OK> (8) the menu closes and the settings will be saved.
The button <Cancel> (9) closes the menu without taking over the carried out
changes.