Group 8 Job editor Page 256
Release R2.0 LEIBINGER JET3
8.5.2.1 Encoder source
(StrokeGo-source)
With this setting you can define the encoder source.
Internal: If this function is activated, the signal is generated by the printer and
needs no external encoder device.
Additionally you have to enter the <Internal speed (intern Speed)> (3).
ATTENTION
You should only work with an internal encoder source if the product is
always directed at the print head with a fix defined and constant speed.
For unsteady production speeds a distortion of the print image can be
caused.
You will find further information regarding this topic in the chapter
Internal speed!
External: If this function is activated the signal has to be generated by an external
encoder (e.g. incremental encoder). The encoder has to be connected to the
interface X1 of the LEIBINGER JET3.
Additionally you have to define the <Encoder/Direction> (4) and the
<Resolution> (5).
Figure 140
StrokeGo-source /Encoder source
Encoder source
1 Checkbox <Encoder source int.>
5 Display field <Resolution>
2 Checkbox <Encoder source ext.>
6 Checkbox <lock backward>
3 Display field <Internal speed>
7 Setting for <Speed depend. output>
4 Checkbox <Encoder/Direction>
1
3
2
6
5
4
7