Type | Surgical Microscope |
---|---|
Focusing | Motorized |
Integrated HD Video Camera | Optional |
Power Supply | 100-240 V AC, 50/60 Hz |
Illumination | LED |
Objective Lens | f=200mm |
Eyepieces | 10x widefield eyepieces (other options may be available) |
Zoom | Motorized, 6:1 zoom ratio |
Stand | Floor stand, ceiling mount |
Fluorescence Modules | Optional |
Working Distance | 200 mm |
Field of View | Varies depending on magnification and objective lens |
Details the extent of liability and disclaimers.
Explains the purpose and content of the user manual.
Explains the meaning of symbols used throughout the manual.
Describes the intended purpose and application of the microscope.
Specifies suitable applications and necessary user qualifications.
Lists any situations or conditions where the product should not be used.
Guidelines for the individual responsible for the instrument's safe operation.
Instructions for personnel operating the microscope.
Details potential risks and precautions regarding light exposure.
Recommended maximum exposure times for OttoFlex™ illuminator.
Identifies risks associated with moving components of the microscope.
Lists various dangers and hazards associated with using the microscope.
Identifies and explains various signs and labels on the microscope.
Details the components and layout of the M822 F20 model.
Illustrates and labels the parts of the M822 F40 model.
Shows and labels the components of the M822 C40 ceiling mount model.
Describes the optics carrier with integrated illumination.
Explains the main light and OttoFlex™ illumination systems.
Details the mechanism and adjustment for balancing the microscope.
Explains the function and operation of the electromagnetic brakes.
Describes the front view and terminals of the control unit.
Identifies and explains the various controls on the microscope itself.
Explains the configuration and assignment of footswitch and handles.
Provides safety warnings and procedures for transporting the microscope.
Step-by-step guide for moving the F20 model to its transport position.
Instructions for transporting the Leica M822 F40 model.
General warnings and guidelines for installing optical accessories.
Instructions for installing a beam splitter.
Steps for attaching a second observer's attachment.
Instructions for setting the interpupillary distance.
Guide to determining and adjusting diopter settings for users.
How to check and ensure consistent image sharpness across magnifications.
Provides a guide for selecting camera and video adapter accessories.
General safety information and installation steps for the slit illuminator.
Secures the extension plate to the intermediate plate.
Guides on adjusting the brightness safely for the patient.
Steps for connecting the Oculus BIOM system.
Details allowed surgery durations based on slit width and risks.
Risks and connection procedures for wide-angle observation systems.
Procedures for releasing and locking the swing arm on the F20 stand.
How to adjust the resistance of the microscope's joints.
Balancing and locking/releasing the swing arm on F40/C40 stands.
Instructions on how to release the microscope's brakes.
Guidelines for safely positioning the microscope at the operating table.
Procedures for attaching sterile controls and drapes for infection control.
How to attach the protective glass to the objective.
Step-by-step guide for powering on the surgical microscope.
Instructions for coarse positioning of the microscope.
Details on using the joystick for precise microscope positioning.
How to adjust the tilt of the microscope.
Configuration of drive speeds and linked settings for zoom, focus, and XY.
How to adjust brightness and contrast using the touch panel or footswitch.
Guide to adjusting the magnification using the control unit or footswitch.
Instructions for adjusting focus using footswitch or reset keys.
Warnings and procedures for moving the microscope to its transport position.
How to move the microscope to its rest position after use.
Steps to properly power down the microscope system.
How to adjust brightness and contrast on the touch panel.
Steps for powering on the microscope and checking its readiness.
How to select and manage user profiles for settings.
Procedures for moving, setting favorites, deleting, and renaming users.
Overview of the User Settings menu for configuration.
How to save current settings or create new user profiles.
Configuring initial speeds for zoom, focus, XY, and tilt drives.
Assigning functions to footswitch buttons for individual users.
Storing diopter values, interpupillary distance, and Depth Enhancer settings.
Saving and running sequences of operations for specific procedures.
Procedure to test footswitches and handles.
Entering accessories to ensure correct magnification display.
Lists Leica-manufactured components like filters, tubes, and assistants.
Lists Leica accessories like DI C800, eyepieces, beam splitters, and objectives.
Lists Leica accessories like slit illuminator, protective glass, and BIOM.
Lists accessories from Leica and third parties, including cameras, monitors, and footswitches.
General guidelines for maintaining the microscope and accessories.
Steps for safely cleaning the touch panel display.
Instructions for safely changing fuses in power input and auxiliary sockets.
Procedures for changing bulbs in the slit illuminator and main light.
Instructions for replacing bulbs in the OttoFlex™ illuminator.
Detailed instructions for workplace, storage, cleaning, and packaging of products.
Lists permissible sterilization methods for various microscope components.
Troubleshooting guide for common problems with the microscope.
Troubleshooting common issues related to footswitch activation.
Troubleshooting issues related to microscope light and bulb functionality.
Troubleshooting problems with the control unit display.
Explains error messages and their corresponding remedies.
Troubleshooting issues specific to the F20 stand.
Troubleshooting common problems encountered with the F40 stand.
Troubleshooting issues related to the movement of the C40 ceiling mount.
Troubleshooting issues with camera image quality and focus.
Technical specifications for the microscope's optics, magnification, and XY unit.
Technical details on the main and coaxial OttoFlex™ illumination systems.
Power socket specifications and consumption for different stand types.
Optical specifications including magnification and field of view.
Specifications for F20 and F40 floor stands, and C40 ceiling mount.
Warning about load limits and links to weight configurations.
Detailed list of weights for various microscope configurations and accessories.
Provides dimensional drawings for the M822 F20 model.
Presents dimensional drawings and movement ranges for the M822 F40.
Shows dimensional drawings and articulation ranges for the M822 C40.
A pre-operation checklist covering setup, functions, and sterility.