EasyManua.ls Logo

LEM Procon 2200P - User Manual

Default Icon
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Index
Soldering point.
Male connector.
Female connector.
M/F faston connector.
Test point.
Supply voltage. Logic supply ground.
Analog supply ground.
Chassis ground.
Earth ground.
Flag joined with one or more flags
GENERALMUSIC S.p.A. Sales Division: 47842 S.Giovanni in Marignano (RN) ITALY - Via delle Rose, 12
Phone +39(0)541/959511 - Fax +39(0)541/957404 - Internet: www.generalmusic.com
Technical specifications, transistor packages, Procon 400p test procedures.2
Procon 750p, Procon 1000p test procedures.3
Procon 1250p, Procon 1500p test procedures.
6
7 Procon 750p schematic.
8
Procon 400p schematic.
9 Procon 1250p schematic.
10
Procon 1000p schematic.
Procon 1500p schematic.
11 Procon 1800p schematic.
12 Procon 2200p schematic.
13 Spare part list.
4
Procon 1800p, Procon 2200p test procedures. 5
with the same signal name inscribed.
ATTENTION Observe precautions when handling electrostatic sensitive devices.
Notice
Service must be carried out by qualified personnel only. Any tampering carried out by unqualified personnel during the guarantee period
will forfeit the right to guarantee.
For a correct operation of the instrument, after having switched off, be careful to wait at least 3 seconds before switching on again.
To improve the device's specifications, the schematic diagrams may be subject to change without prior notice.
All components marked by this symbol have special safety characteristics, when replacing any of these components use only
manufacturer's specified parts.
The (µ) micro symbol of capacitance value is substituted by U.
The (
) omega symbol of resistance value is substituted by E.
The electrolytic capacitors are 25Vdc rated voltage unless otherwise specified.
All resistors are 1/8W unless otherwise specified.
All switches shown in the "OFF" position. All DC voltages measured to ground with a voltmeter 20KOhm/V.
service manual
schematic diagrams
CODE: 270312
Power Amplifiers
procon plus
Question and Answer IconNeed help?

Do you have a question about the LEM Procon 2200P and is the answer not in the manual?

Summary

Operational Notice and Safety Guidelines

Procon Plus Series Technical Specifications

Procon 400 p Test Procedures

Procon 750 p Test Procedures

Procon 1000 p Test Procedures

Procon 1250 p Test Procedures

Procon 1500 p Test Procedures

Procon 1800 p Test Procedures

Procon 2200 p Test Procedures

Precautionary Measures for Testing

Essential safety precautions to prevent short circuits, damage, and ensure personnel safety during testing procedures.

Power Supply Voltage Verification

Steps to verify AC and DC supply voltages using a multimeter, checking insulation, and monitoring for correct operation.

Channel Performance Check

Procedure for checking amplifier channel performance, output signal symmetry, distortion, and fan speed response.

Spare Part List and Component Legend

Summary

Operational Notice and Safety Guidelines

Procon Plus Series Technical Specifications

Procon 400 p Test Procedures

Procon 750 p Test Procedures

Procon 1000 p Test Procedures

Procon 1250 p Test Procedures

Procon 1500 p Test Procedures

Procon 1800 p Test Procedures

Procon 2200 p Test Procedures

Precautionary Measures for Testing

Essential safety precautions to prevent short circuits, damage, and ensure personnel safety during testing procedures.

Power Supply Voltage Verification

Steps to verify AC and DC supply voltages using a multimeter, checking insulation, and monitoring for correct operation.

Channel Performance Check

Procedure for checking amplifier channel performance, output signal symmetry, distortion, and fan speed response.

Spare Part List and Component Legend

LEM Procon 2200P Specifications

General IconGeneral
BrandLEM
ModelProcon 2200P
CategoryAmplifier