14ACX - 1.5 to 5 Ton Air Conditioner / Page 122
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A TXV 40,500 14.50 12.20 CX35-36B SLP98UH070XV36B 8258509
14ACXS042-230A TXV 40,500 14.25 12.00 CX35-36B 8258500
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48B EL180UH090E48B 8258516
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48B EL180UH090XE48B 8258520
14ACXS042-230A TXV 41,000 14.50 12.20 CX35-48B EL296UH045XV36B 8258521
14ACXS042-230A TXV 41,000 14.50 12.20 CX35-48B EL296UH070XV36B 8258523
14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48B SL280UH090V36B 8258525
14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48B SL280UH090V48B 8258527
14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48B SL280UH090XV48B 8258528
14ACXS042-230A TXV 41,000 14.50 12.20 CX35-48B SLP98UH070XV36B 8258518
14ACXS042-230A TXV 41,000 14.25 12.00 CX35-48B 8258514
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH090E60C 8258542
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH110E60C 8258556
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH110XE60C 8258543
14ACXS042-230A TXV 41,000 15.50 12.50 CX35-48C EL195UH090XE48C 8258557
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL195UH110XE60C 8258545
14ACXS042-230A TXV 41,000 15.50 12.50 CX35-48C EL296UH090XE48C 8258559
14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C EL296UH090XV36C 8258561
14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C EL296UH090XV48C 8258562
14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48C EL296UH090XV60C 8258532
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL296UH110XE60C 8258564
14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48C EL296UH110XV48C 8258533
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL296UH110XV60C 8258547
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH090V60C 8258535
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH090XV60C 8258549
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH110V60C 8258537
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH110XV60C 8258550
14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C SLP98UH090XV36C 8258539
14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C SLP98UH090XV48C 8258552
14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48C SLP98UH090XV60C 8258540
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SLP98UH110XV60C 8258554
14ACXS042-230A TXV 41,000 14.25 12.00 CX35-48C 8258530
14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH090E60C 8258592
14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH110E60C 8258572
14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH110XE60C 8258594
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL195UH090XE48C 8258574
14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL195UH110XE60C 8258596
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XE48C 8258576
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XV36C 8258597
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XV48C 8258577
14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH090XV60C 8258599
14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XE60C 8258582
14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XV48C 8258568
14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XV60C 8258584
14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C SL280UH090V60C 8258569
14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C SL280UH090XV60C 8258586
14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C SL280UH110V60C 8258587
14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C SL280UH110XV60C 8258589
14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C SLP98UH090XV36C 8258591
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.