14ACX - 1.5 to 5 Ton Air Conditioner / Page 14
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090E48B 5735107
14ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090XE48B 5737071
14ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090E48B 5735136
14ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090XE48B 5737122
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090E48B 5735109
14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH090E60C 5736008
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090XE48B 5737073
14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110E60C 5737832
14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110XE60C 5738903
14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL195UH090XE48C 4693850
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL195UH110XE60C 4693864
14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH090XE48C 5647286
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL296UH110XE60C 5647249
14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH110XV48C 5685129
14ACX-041-230 TXV 37,800 14.70 12.50 C33-43 SL280UH070V36A 5077316
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090V60C 3869093
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090XV60C 4235235
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110V60C 3869094
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110XV60C 4040070
14ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090E48B 5735111
14ACX-041-230 TXV 38,500 15.50 13.20 C33-48 EL180UH090E60C 5736010
14ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090XE48B 5737074
14ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110E60C 5737834
14ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110XE60C 5738904
14ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL195UH090XE48C 4693851
14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL195UH110XE60C 4693865
14ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL296UH090XE48C 5647236
14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XE60C 5647250
14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XV48C 5685130
14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH090E60C 5736012
14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110E60C 5737836
14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110XE60C 5738912
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH090XE48C 4693852
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH110XE60C 4693866
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH090XE48C 5647237
14ACX-041-230 TXV 39,500 15.50 12.50 C33-49 EL296UH090XV48C 7492822
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XE60C 5647251
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XV48C 5685131
14ACX-041-230 TXV 38,500 14.50 12.50 C33-49 3869096
14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH090E60C 5736014
14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110E60C 5737838
14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110XE60C 5738915
14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL195UH090XE48C 4693853
14ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL195UH110XE60C 4693867
14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH090XE48C 5647238
14ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL296UH110XE60C 5647252
14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH110XV48C 5685132
14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH090E60C 5736016
14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH110E60C 5737839
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.