AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090E48B 5735107
14ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090XE48B 5737071
14ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090E48B 5735136
14ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090XE48B 5737122
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090E48B 5735109
14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH090E60C 5736008
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090XE48B 5737073
14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110E60C 5737832
14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110XE60C 5738903
14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL195UH090XE48C 4693850
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL195UH110XE60C 4693864
14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH090XE48C 5647286
14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL296UH110XE60C 5647249
14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH110XV48C 5685129
14ACX-041-230 TXV 37,800 14.70 12.50 C33-43 SL280UH070V36A 5077316
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090V60C 3869093
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090XV60C 4235235
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110V60C 3869094
14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110XV60C 4040070
14ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090E48B 5735111
14ACX-041-230 TXV 38,500 15.50 13.20 C33-48 EL180UH090E60C 5736010
14ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090XE48B 5737074
14ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110E60C 5737834
14ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110XE60C 5738904
14ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL195UH090XE48C 4693851
14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL195UH110XE60C 4693865
14ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL296UH090XE48C 5647236
14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XE60C 5647250
14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XV48C 5685130
14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH090E60C 5736012
14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110E60C 5737836
14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110XE60C 5738912
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH090XE48C 4693852
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH110XE60C 4693866
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH090XE48C 5647237
14ACX-041-230 TXV 39,500 15.50 12.50 C33-49 EL296UH090XV48C 7492822
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XE60C 5647251
14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XV48C 5685131
14ACX-041-230 TXV 38,500 14.50 12.50 C33-49 3869096
14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH090E60C 5736014
14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110E60C 5737838
14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110XE60C 5738915
14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL195UH090XE48C 4693853
14ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL195UH110XE60C 4693867
14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH090XE48C 5647238
14ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL296UH110XE60C 5647252
14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH110XV48C 5685132
14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH090E60C 5736016
14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH110E60C 5737839
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.