AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-030-230A TXV 28,000 14.50 12.20 CX35-48C 8268487
14ACX-036-230A RFC 34,000 14.25 12.20 C33-43 7513149
14ACX-036-230A RFC 34,400 14.25 12.20 C33-49 7513151
14ACX-036-230A RFC 34,000 14.25 12.20 C33-50/60C 7510368
14ACX-036-230A RFC 34,400 14.00 12.20 C35-49C 8471018
14ACX-036-230A RFC 34,000 14.00 12.20 C35-50/60C 8471020
14ACX-036-230A RFC 33,800 14.00 12.20 CH33-31B 7510456
14ACX-036-230A RFC 34,600 14.50 12.20 CH33-43B 7510507
14ACX-036-230A RFC 34,000 14.25 12.20 CH33-44/48B 7510541
14ACX-036-230A RFC 34,000 14.25 12.20 CH33-48 7513192
14ACX-036-230A RFC 34,600 14.50 12.20 CH33-49 7513193
14ACX-036-230A RFC 34,400 14.25 12.20 CH33-50/60C 7510594
14ACX-036-230A TXV 34,200 15.10 12.50 C33-31A EL180UH045E36A 7510237
14ACX-036-230A TXV 34,200 15.10 12.50 C33-31A EL180UH045XE36A 7510238
14ACX-036-230A TXV 34,400 15.10 12.50 C33-31A SL280UH070V36A 7510235
14ACX-036-230A TXV 34,400 15.10 12.50 C33-31A SL280UH070XV36A 7510236
14ACX-036-230A TXV 34,400 15.00 12.50 C33-31B EL180UH070E36B 7510244
14ACX-036-230A TXV 34,400 15.00 12.50 C33-31B EL180UH070XE36B 7510245
14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B EL180UH090E48B 7510246
14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B EL180UH090XE48B 7510247
14ACX-036-230A TXV 34,000 14.50 12.20 C33-31B EL195UH045XE36B 7510248
14ACX-036-230A TXV 34,000 15.10 12.50 C33-31B EL195UH070XE36B 7510250
14ACX-036-230A TXV 34,000 14.50 12.20 C33-31B EL296UH045XE36B 7510249
14ACX-036-230A TXV 34,200 15.10 12.50 C33-31B EL296UH045XV36B 7510252
14ACX-036-230A TXV 34,000 15.10 12.50 C33-31B EL296UH070XE36B 7510251
14ACX-036-230A TXV 34,200 15.10 12.50 C33-31B EL296UH070XV36B 7510253
14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090V36B 7510241
14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090V48B 7510242
14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090XV48B 7510243
14ACX-036-230A TXV 34,200 15.10 12.50 C33-31B SLP98UH070XV36B 7510254
14ACX-036-230A TXV 33,200 14.50 12.20 C33-36A EL180UH045E36A 7510258
14ACX-036-230A TXV 33,200 14.50 12.20 C33-36A EL180UH045XE36A 7510259
14ACX-036-230A TXV 33,400 15.00 12.20 C33-36A SL280UH070V36A 7510256
14ACX-036-230A TXV 33,400 15.00 12.20 C33-36A SL280UH070XV36A 7510257
14ACX-036-230A TXV 33,400 15.50 12.50 C33-36B EL180UH070E36B 7510264
14ACX-036-230A TXV 33,400 15.50 12.50 C33-36B EL180UH070XE36B 7510265
14ACX-036-230A TXV 33,400 15.10 12.50 C33-36B EL180UH090E48B 7510266
14ACX-036-230A TXV 33,400 15.10 12.50 C33-36B EL180UH090XE48B 7510267
14ACX-036-230A TXV 33,000 15.00 12.50 C33-36B EL195UH045XE36B 7510268
14ACX-036-230A TXV 33,000 15.00 12.50 C33-36B EL296UH045XE36B 7510269
14ACX-036-230A TXV 33,400 15.00 12.50 C33-36B EL296UH045XV36B 7510272
14ACX-036-230A TXV 33,400 15.00 12.50 C33-36B EL296UH070XV36B 7510273
14ACX-036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090V36B 7510261
14ACX-036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090V48B 7510262
14ACX-036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090XV48B 7510263
14ACX-036-230A TXV 33,400 15.00 12.50 C33-36B SLP98UH070XV36B 7510274
14ACX-036-230A TXV 33,600 15.10 12.50 C33-36C EL180UH090E60C 7510276
14ACX-036-230A TXV 33,400 15.50 12.50 C33-36C EL180UH110E60C 7510277
14ACX-036-230A TXV 33,400 15.50 12.50 C33-36C EL180UH110XE60C 7510278
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.