SPECIFICATIONS
General
Data
Model No. All Regions - - - - - - - - - - - - 14ACX-041
North / South Regions 14ACXS018 14ACXS024 14ACXS030 14ACXS036 - - -
Southwest Region 14ACX-018 14ACX-024 14ACX-030 14ACX-036 - - -
Nominal Tonnage 1.5 2 2.5 3 3.5
Connections
(sweat)
Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8
Suction line o.d. - in. 3/4 3/4 3/4 7/8 7/8
1
Refrigerant (R-410A) furnished 4 lbs. 13 oz. 5 lbs. 6 oz. 6 lbs. 11 oz. 6 lbs. 11 oz. 10 lbs. 1 oz.
Outdoor
Coil
Net face area
sq. ft.
Outer coil 13.22 16 21 21 21
Inner coil - - - - - - - - - - - - 20.25
Tube diameter - in. 5/16 5/16 5/16 5/16 5/16
Number of rows 1 1 1 1 2
Fins per inch 26 26 26 26 22
Outdoor
Fan
Diameter - in. 18 22 22 22 22
Number of blades 3 3 3 3 4
Motor hp 1/10 1/6 1/6 1/6 1/4
Cfm 2290 3160 3160 3160 3600
Rpm 1075 825 825 825 825
Watts 160 215 215 215 310
Shipping Data - lbs. 1 package 138 158 171 177 209
ELECTRICAL DATA
Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V
2
Maximum overcurrent protection (amps) 20 25 25 30 35
3
Minimum circuit ampacity 12.4 15.0 17.1 18.6 22.6
Compressor Rated load amps 9.4 11.2 12.9 14.1 16.7
Locked rotor amps 56.6 60.8 64 77 79
Power factor 0.96 0.97 0.98 0.98 0.97
Condenser
Fan Motor
Full load amps 0.7 1.0 1.0 1.0 1.7
Locked rotor amps 1.3 1.9 1.9 1.9 3.2
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Crankcase Heater 93M04 • • • •
Factory •
Compressor Hard Start Kit 10J42 • •
88M91 • • •
Compressor Low Ambient Cut-Off Switch 45F08 • • • • •
Compressor Sound Cover 27W55 • • • •
27W56 •
Compressor Time-Off Control 47J27 • • • • •
Freezestat 3/8 in. tubing 93G35 • • • • •
5/8 in. tubing 50A93 • • • • •
Indoor Blower Off Delay Relay 58M81 • • • • •
Loss of Charge Switch Kit 84M23 • • • • •
4
Low Ambient Kit (Fan Cycling) 34M72 • • • • •
Mounting Base 69J06 •
69J07 • • • •
Refrigerant Line
Sets
L15-41-20, L15-41-30,
L15-41-40, L15-41-50
• • •
L15-65-30, L15-65-40,
L15-65-50
• •
Unit Stand-Off Kit 94J45 • • • • •
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufcient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and
additional refrigerant charge required.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.