14ACX - 1.5 to 5 Ton Air Conditioner / Page 133
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL180UH070E36B 8268543
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL180UH070XE36B 8268544
14ACX-024-230A TXV 24,000 15.50 12.50 C35-30/36B EL195UH030XE24B 8608856
14ACX-024-230A TXV 24,000 15.50 12.50 C35-30/36B EL195UH045XE24B 8608857
14ACX-024-230A TXV 23,400 15.50 12.50 C35-30/36B EL195UH045XE36B 8268545
14ACX-024-230A TXV 23,600 16.00 13.00 C35-30/36B EL195UH070XE36B 8268534
14ACX-024-230A TXV 23,400 15.50 12.50 C35-30/36B EL296UH045XE36B 8268535
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL296UH045XV36B 8268537
14ACX-024-230A TXV 23,600 16.00 13.00 C35-30/36B EL296UH070XE36B 8268536
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL296UH070XV36B 8268538
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090V36B 8268540
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090V48B 8268541
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090XV48B 8268542
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SLP98UH070XV36B 8268539
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36C EL296UH090XV36C 8268546
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36C SLP98UH090XV36C 8268547
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A EL180UH045E36A 8268513
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A EL180UH045XE36A 8268514
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A SL280UH070V36A 8268515
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A SL280UH070XV36A 8268516
14ACX-024-230A TXV 24,000 14.50 12.20 C35-30A 8268512
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL180UH070E36B 8268529
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL180UH070XE36B 8268520
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH030XE24B 8608858
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH045XE24B 8608859
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH045XE36B 8268521
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH070XE36B 8268522
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH045XE36B 8268523
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH045XV36B 8268525
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH070XE36B 8268524
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH070XV36B 8268518
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090V36B 8268526
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090V48B 8268527
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090XV48B 8268528
14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SLP98UH070XV36B 8268519
14ACX-024-230A TXV 24,000 14.50 12.20 C35-30B 8268517
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36A EL180UH045E36A 8268551
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36A EL180UH045XE36A 8268552
14ACX-024-230A TXV 24,000 16.00 13.50 C35-36A SL280UH070V36A 8268549
14ACX-024-230A TXV 24,000 16.00 13.50 C35-36A SL280UH070XV36A 8268550
14ACX-024-230A TXV 24,000 14.50 12.50 C35-36A 8268548
14ACX-024-230A TXV 24,000 16.00 13.50 C35-36B EL180UH070E36B 8268563
14ACX-024-230A TXV 24,000 16.00 13.50 C35-36B EL180UH070XE36B 8268564
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH030XE24B 8608860
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH045XE24B 8608861
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH045XE36B 8268565
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH070XE36B 8268554
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH045XE36B 8268555
14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH045XV36B 8268557
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.