AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH110XE60C 8268144
14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH110XV48C 8268138
14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C EL296UH110XV60C 8268139
14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C SL280UH090V60C 8268153
14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C SL280UH090XV60C 8268147
14ACX-036-230A TXV 35,400 16.00 13.00 C35-49C SL280UH110V60C 8268148
14ACX-036-230A TXV 35,400 16.00 13.00 C35-49C SL280UH110XV60C 8268149
14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C SLP98UH090XV36C 8268146
14ACX-036-230A TXV 35,000 16.00 13.00 C35-49C SLP98UH090XV48C 8268137
14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C SLP98UH110XV60C 8268140
14ACX-036-230A TXV 34,600 14.50 12.20 C35-49C 8268135
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH090E60C 8268171
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH110E60C 8268172
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH110XE60C 8268161
14ACX-036-230A TXV 34,400 15.50 12.50 C35-50/60C EL195UH090XE48C 8268162
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL195UH110XE60C 8268164
14ACX-036-230A TXV 34,400 15.50 12.50 C35-50/60C EL296UH090XE48C 8268163
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH090XV36C 8268166
14ACX-036-230A TXV 34,600 16.00 13.00 C35-50/60C EL296UH090XV48C 8268156
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH110XE60C 8268165
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH110XV48C 8268158
14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C EL296UH110XV60C 8268159
14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C SL280UH090V60C 8268167
14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C SL280UH090XV60C 8268168
14ACX-036-230A TXV 35,000 16.00 13.00 C35-50/60C SL280UH110V60C 8268169
14ACX-036-230A TXV 35,000 16.00 13.00 C35-50/60C SL280UH110XV60C 8268170
14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C SLP98UH090XV36C 8268155
14ACX-036-230A TXV 34,600 16.00 13.00 C35-50/60C SLP98UH090XV48C 8268157
14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C SLP98UH110XV60C 8268160
14ACX-036-230A TXV 34,200 14.50 12.20 C35-50/60C 8268154
14ACX-036-230A TXV 34,200 14.50 12.20 CBX25UH-036 7510388
14ACX-036-230A TXV 34,600 15.00 12.50 CBX25UH-042 7510389
14ACX-036-230A TXV 34,400 15.00 12.50 CBX25UHV-036 7510390
14ACX-036-230A TXV 35,200 16.00 13.00 CBX25UHV-042 7510391
14ACX-036-230A TXV 34,200 16.00 13.00 CBX27UH-036 7510392
14ACX-036-230A TXV 35,200 16.00 13.00 CBX27UH-042 7510393
14ACX-036-230A TXV 33,400 14.50 12.20 CBX32M-030 7510394
14ACX-036-230A TXV 33,800 14.50 12.20 CBX32M-036 7510395
14ACX-036-230A TXV 33,800 14.50 12.20 CBX32M-042 7510396
14ACX-036-230A TXV 34,800 15.10 12.50 CBX32M-048 7510397
14ACX-036-230A TXV 34,000 15.10 12.50 CBX32MV-036 7510398
14ACX-036-230A TXV 35,200 16.00 13.00 CBX32MV-048 7510399
14ACX-036-230A TXV 34,200 15.10 12.50 CBX40UHV-036 7510400
14ACX-036-230A TXV 35,000 15.50 12.50 CBX40UHV-042 7510401
14ACX-036-230A TXV 35,000 16.00 13.00 CBX40UHV-048 7510402
14ACX-036-230A TXV 33,600 15.00 12.50 CH23-41 EL180UH045E36A 7510406
14ACX-036-230A TXV 33,600 15.00 12.50 CH23-41 EL180UH045XE36A 7510407
14ACX-036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH070E36B 7510408
14ACX-036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH070XE36B 7510409
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.