EasyManua.ls Logo

Lennox 14ACx–024-230A02 - Page 176

Lennox 14ACx–024-230A02
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14ACX - 1.5 to 5 Ton Air Conditioner / Page 176
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-036-230A TXV 34,400 14.50 12.20 CX35-48C 8268255
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL180UH090E60C 8268287
14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C EL180UH110E60C 8268288
14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C EL180UH110XE60C 8268289
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-49C EL195UH090XE48C 8268290
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL195UH110XE60C 8268280
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-49C EL296UH090XE48C 8268279
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH090XV36C 8268282
14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C EL296UH090XV48C 8268284
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH110XE60C 8268281
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH110XV48C 8268276
14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C EL296UH110XV60C 8268277
14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C SL280UH090V60C 8268291
14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C SL280UH090XV60C 8268292
14ACX-036-230A TXV 35,400 16.00 13.00 CX35-49C SL280UH110V60C 8268285
14ACX-036-230A TXV 35,400 16.00 13.00 CX35-49C SL280UH110XV60C 8268286
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C SLP98UH090XV36C 8268283
14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C SLP98UH090XV48C 8268275
14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C SLP98UH110XV60C 8268278
14ACX-036-230A TXV 34,600 14.50 12.20 CX35-49C 8268274
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH090E60C 8268302
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH110E60C 8268303
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH110XE60C 8268304
14ACX-036-230A TXV 34,400 15.50 12.50 CX35-50/60C EL195UH090XE48C 8268305
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL195UH110XE60C 8268307
14ACX-036-230A TXV 34,400 15.50 12.50 CX35-50/60C EL296UH090XE48C 8268306
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH090XV36C 8268297
14ACX-036-230A TXV 34,600 16.00 13.00 CX35-50/60C EL296UH090XV48C 8268299
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH110XE60C 8268296
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH110XV48C 8268301
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C EL296UH110XV60C 8268294
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C SL280UH090V60C 8268308
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C SL280UH090XV60C 8268309
14ACX-036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110V60C 8268310
14ACX-036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110XV60C 8268311
14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C SLP98UH090XV36C 8268298
14ACX-036-230A TXV 34,600 16.00 13.00 CX35-50/60C SLP98UH090XV48C 8268300
14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C SLP98UH110XV60C 8268295
14ACX-036-230A TXV 34,200 14.50 12.20 CX35-50/60C 8268293
14ACX-042-230A RFC 42,000 14.25 12.20 C33-62C 7511091
14ACX-042-230A RFC 41,500 14.00 12.20 C35-49C 8471019
14ACX-042-230A RFC 41,000 14.00 12.20 C35-60D 8471021
14ACX-042-230A RFC 41,500 14.00 12.20 CH33-43C 7513072
14ACX-042-230A RFC 42,000 14.00 12.20 CH33-49 7511217
14ACX-042-230A RFC 41,500 14.00 12.20 CH33-50/60C 7511239
14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090E48B 7510967
14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090XE48B 7510968
14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V36B 7510961
14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V48B 7510962
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.