14ACX - 1.5 to 5 Ton Air Conditioner / Page 189
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL180UH090E60C 7511448
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110E60C 7511449
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110XE60C 7511450
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL195UH090XE48C 7511451
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL195UH110XE60C 7511453
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XE48C 7511452
14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C EL296UH090XV36C 7511455
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XV48C 7511456
14ACX-042-230A TXV 41,000 15.00 12.50 CX34-44/48C EL296UH090XV60C 7511457
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL296UH110XE60C 7511454
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV48C 7511458
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV60C 7511459
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090V60C 7511460
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090XV60C 7511461
14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110V60C 7511462
14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110XV60C 7511463
14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C SLP98UH090XV36C 7511464
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH090XV48C 7511465
14ACX-042-230A TXV 41,000 15.00 12.50 CX34-44/48C SLP98UH090XV60C 7511466
14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH110XV60C 7511467
14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH090E60C 7511469
14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110E60C 7511470
14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110XE60C 7511471
14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL195UH090XE48C 7511472
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL195UH110XE60C 7511473
14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XE48C 7511474
14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV36C 7511475
14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV48C 7511476
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH090XV60C 7511477
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XE60C 7511478
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XV48C 7511479
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XV60C 7511480
14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 SL280UH090V60C 7511481
14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 SL280UH090XV60C 7511482
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SL280UH110V60C 7511483
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SL280UH110XV60C 7511484
14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 SLP98UH090XV36C 7511485
14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 SLP98UH090XV48C 7511486
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SLP98UH090XV60C 7511487
14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SLP98UH110XV60C 7511488
14ACX-042-230A TXV 41,500 14.25 12.20 CX34-49 7511468
14ACX-042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH090E60C 7511490
14ACX-042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH110E60C 7511491
14ACX-042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH110XE60C 7511492
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL195UH090XE48C 7511493
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL195UH110XE60C 7511494
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XE48C 7511495
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV36C 7511496
14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV48C 7511497
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.