AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-047-230 TXV 46,500 14.70 12.20 CH33-48 EL180UH110E60C 5737843
14ACX-047-230 TXV 46,500 14.70 12.20 CH33-48 EL180UH110XE60C 5738921
14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 EL296UH090XV48C 5057275
14ACX-047-230 TXV 46,000 14.70 12.20 CH33-48 EL296UH090XV60C 5057276
14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 EL296UH110XV60C 5057277
14ACX-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090V60C 3869180
14ACX-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090XV60C 4235242
14ACX-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110V60C 3869181
14ACX-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110XV60C 4040143
14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH090XV48C 5140465
14ACX-047-230 TXV 46,000 14.70 12.20 CH33-48 SLP98UH090XV60C 5140466
14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH110XV60C 5140467
14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL195UH090XE48C 4693924
14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL195UH110XE60C 4693936
14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL296UH090XE48C 5647269
14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL296UH110XE60C 5647232
14ACX-047-230 TXV 45,500 14.25 12.00 CH33-48C 7426646
14ACX-047-230 TXV 46,500 15.50 12.70 CH33-49 EL180UH090E60C 5736022
14ACX-047-230 TXV 47,500 15.20 12.70 CH33-49 EL180UH110E60C 5737845
14ACX-047-230 TXV 47,500 15.20 12.70 CH33-49 EL180UH110XE60C 5738922
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL195UH090XE48C 4693925
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL195UH110XE60C 4693937
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL296UH090XE48C 5647270
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH090XV48C 5057284
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH090XV60C 5057285
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL296UH110XE60C 5647233
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH110XV60C 5057286
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090XV48C 5140537
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090XV60C 5140538
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH110XV60C 5140539
14ACX-047-230 TXV 46,500 14.50 12.00 CH33-49 7426652
14ACX-047-230 TXV 46,500 15.50 12.70 CH33-50/60C EL180UH090E60C 5736024
14ACX-047-230 TXV 47,000 15.00 12.50 CH33-50/60C EL180UH110E60C 5737847
14ACX-047-230 TXV 47,000 15.00 12.50 CH33-50/60C EL180UH110XE60C 5738925
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL195UH090XE48C 4693926
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL195UH110XE60C 4693938
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL296UH090XE48C 5647271
14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL296UH110XE60C 5647234
14ACX-047-230 TXV 46,500 14.50 12.20 CH33-50/60C 4253835
14ACX-047-230 TXV 46,500 15.50 12.70 CH33-60D EL180UH135E60D 5746070
14ACX-047-230 TXV 46,500 15.00 12.50 CH33-60D EL195UH135XE60D 4693945
14ACX-047-230 TXV 46,500 15.00 12.50 CH33-60D EL296UH135XE60D 5647281
14ACX-047-230 TXV 46,000 14.25 12.00 CH33-60D 7426647
14ACX-047-230 TXV 47,000 15.70 13.00 CH33-62D EL180UH135E60D 5746071
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-62D EL195UH135XE60D 4693946
14ACX-047-230 TXV 47,000 15.20 12.70 CH33-62D EL296UH135XE60D 5647282
14ACX-047-230 TXV 46,500 14.50 12.00 CH33-62D 7426648
14ACX-047-230 TXV 47,500 15.50 12.50 CH35-42B EL180UH090E48B 7163952
14ACX-047-230 TXV 47,500 15.00 12.50 CH35-42B SL280UH090XV48B 7163955
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.