14ACX - 1.5 to 5 Ton Air Conditioner / Page 53
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS018-230A TXV 19,800 16.00 13.00 CBX40UHV-030 7625283
14ACXS018-230A TXV 17,900 14.25 11.50 CH33-18A EL180UH045E36A 7625287
14ACXS018-230A TXV 17,900 14.25 11.50 CH33-18A EL180UH045XE36A 7625285
14ACXS018-230A TXV 19,400 16.00 13.00 CH33-19 EL180UH045E36A 7625385
14ACXS018-230A TXV 19,400 16.00 13.00 CH33-19 EL180UH045XE36A 7625384
14ACXS018-230A TXV 18,800 14.00 11.50 CH33-19 7625383
14ACXS018-230A TXV 19,300 16.00 13.00 CH33-24/30 EL180UH045E36A 7625388
14ACXS018-230A TXV 19,300 16.00 13.00 CH33-24/30 EL180UH045XE36A 7625387
14ACXS018-230A TXV 18,700 14.00 11.50 CH33-24/30 7625386
14ACXS018-230A TXV 19,800 16.00 13.00 CH33-25A EL180UH045E36A 7625294
14ACXS018-230A TXV 19,800 16.00 13.00 CH33-25A EL180UH045XE36A 7625292
14ACXS018-230A TXV 19,200 14.50 12.20 CH33-25A 7625290
14ACXS018-230A TXV 19,400 15.50 12.50 CH33-25B EL180UH070E36B 7625299
14ACXS018-230A TXV 19,400 15.50 12.50 CH33-25B EL180UH070XE36B 7625298
14ACXS018-230A TXV 18,000 14.25 12.00 CH33-25B EL195UH030XE24B 8606329
14ACXS018-230A TXV 18,000 14.25 12.00 CH33-25B EL195UH045XE24B 8606330
14ACXS018-230A TXV 19,900 16.00 13.00 CH33-25B EL195UH045XE36B 7625301
14ACXS018-230A TXV 19,900 16.00 13.00 CH33-25B EL296UH045XE36B 7625303
14ACXS018-230A TXV 20,200 16.00 13.00 CH33-25B EL296UH045XV36B 7625304
14ACXS018-230A TXV 19,100 14.25 12.00 CH33-25B 7625296
14ACXS018-230A TXV 20,200 16.00 13.00 CH33-31A EL180UH045E36A 7625308
14ACXS018-230A TXV 20,200 16.00 13.00 CH33-31A EL180UH045XE36A 7625307
14ACXS018-230A TXV 19,500 14.50 12.20 CH33-31A 7625306
14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL180UH070E36B 7625312
14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL180UH070XE36B 7625311
14ACXS018-230A TXV 18,000 14.50 12.20 CH33-31B EL195UH030XE24B 8606331
14ACXS018-230A TXV 18,000 14.50 12.20 CH33-31B EL195UH045XE24B 8606332
14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL195UH045XE36B 7625313
14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL296UH045XE36B 7625314
14ACXS018-230A TXV 20,600 16.00 13.50 CH33-31B EL296UH045XV36B 7625315
14ACXS018-230A TXV 19,500 14.50 12.20 CH33-31B 7625310
14ACXS018-230A TXV 19,400 16.00 13.00 CH35-18A EL180UH045E36A 7625318
14ACXS018-230A TXV 19,400 16.00 13.00 CH35-18A EL180UH045XE36A 7625317
14ACXS018-230A TXV 18,800 14.00 11.50 CH35-18A 7625316
14ACXS018-230A TXV 19,900 16.00 13.00 CH35-24A EL180UH045E36A 7625320
14ACXS018-230A TXV 19,900 16.00 13.00 CH35-24A EL180UH045XE36A 7625321
14ACXS018-230A TXV 19,300 14.50 12.20 CH35-24A 7625319
14ACXS018-230A TXV 19,500 15.50 12.50 CH35-24B EL180UH070E36B 7625323
14ACXS018-230A TXV 19,500 15.50 12.50 CH35-24B EL180UH070XE36B 7625324
14ACXS018-230A TXV 18,000 14.25 12.00 CH35-24B EL195UH030XE24B 8606333
14ACXS018-230A TXV 18,000 14.25 12.00 CH35-24B EL195UH045XE24B 8606334
14ACXS018-230A TXV 19,600 15.50 12.50 CH35-24B EL195UH045XE36B 7625325
14ACXS018-230A TXV 19,600 15.50 12.50 CH35-24B EL296UH045XE36B 7625326
14ACXS018-230A TXV 20,200 16.00 13.00 CH35-24B EL296UH045XV36B 7625327
14ACXS018-230A TXV 19,100 14.25 12.00 CH35-24B 7625322
14ACXS018-230A TXV 20,200 16.00 13.00 CH35-30A EL180UH045E36A 7625330
14ACXS018-230A TXV 20,200 16.00 13.00 CH35-30A EL180UH045XE36A 7625329
14ACXS018-230A TXV 19,500 14.50 12.20 CH35-30A 7625328
14ACXS018-230A TXV 19,900 16.00 13.00 CH35-30B EL180UH070E36B 7625332
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.