AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS018-230A TXV 19,900 16.00 13.00 CX34-31A EL180UH045XE36A 7625375
14ACXS018-230A TXV 19,300 14.50 12.20 CX34-31A 7625373
14ACXS018-230A TXV 19,700 15.50 12.50 CX34-31B EL180UH070E36B 7625377
14ACXS018-230A TXV 19,700 15.50 12.50 CX34-31B EL180UH070XE36B 7625378
14ACXS018-230A TXV 18,000 16.00 13.00 CX34-31B EL195UH030XE24B 8606343
14ACXS018-230A TXV 18,000 16.00 13.00 CX34-31B EL195UH045XE24B 8606344
14ACXS018-230A TXV 19,800 16.00 13.00 CX34-31B EL195UH045XE36B 7625379
14ACXS018-230A TXV 19,800 16.00 13.00 CX34-31B EL296UH045XE36B 7625380
14ACXS018-230A TXV 20,400 16.00 13.50 CX34-31B EL296UH045XV36B 7625381
14ACXS018-230A TXV 20,400 16.00 13.50 CX34-31B EL296UH070XV36B 7625382
14ACXS018-230A TXV 20,400 16.00 13.50 CX34-31B SLP98UH070XV36B 7783664
14ACXS018-230A TXV 19,300 14.50 12.20 CX34-31B 7625376
14ACXS018-230A TXV 18,400 15.00 12.50 CX35-18/24A EL180UH045E36A 8260946
14ACXS018-230A TXV 18,400 15.00 12.50 CX35-18/24A EL180UH045XE36A 8260947
14ACXS018-230A TXV 18,500 14.50 12.20 CX35-18/24B EL180UH070E36B 8260949
14ACXS018-230A TXV 18,500 14.50 12.20 CX35-18/24B EL180UH070XE36B 8260951
14ACXS018-230A TXV 18,600 14.50 12.50 CX35-18/24B EL195UH045XE36B 8260952
14ACXS018-230A TXV 18,600 14.50 12.50 CX35-18/24B EL296UH045XE36B 8260954
14ACXS018-230A TXV 19,700 16.00 13.00 CX35-24A EL180UH045E36A 8260959
14ACXS018-230A TXV 19,700 16.00 13.00 CX35-24A EL180UH045XE36A 8260958
14ACXS018-230A TXV 19,200 14.25 12.20 CX35-24A 8260956
14ACXS018-230A TXV 19,500 15.50 12.50 CX35-24B EL180UH070E36B 8260971
14ACXS018-230A TXV 19,500 15.50 12.50 CX35-24B EL180UH070XE36B 8260969
14ACXS018-230A TXV 18,000 14.50 12.20 CX35-24B EL195UH030XE24B 8606345
14ACXS018-230A TXV 18,000 14.50 12.20 CX35-24B EL195UH045XE24B 8606346
14ACXS018-230A TXV 20,000 16.00 13.00 CX35-24B EL195UH045XE36B 8260974
14ACXS018-230A TXV 20,000 16.00 13.00 CX35-24B EL296UH045XE36B 8260975
14ACXS018-230A TXV 20,200 16.00 13.00 CX35-24B EL296UH045XV36B 8260966
14ACXS018-230A TXV 20,200 16.00 13.00 CX35-24B EL296UH070XV36B 8260967
14ACXS018-230A TXV 20,200 16.00 13.00 CX35-24B SLP98UH070XV36B 8260964
14ACXS018-230A TXV 19,200 14.25 12.20 CX35-24B 8260961
14ACXS018-230A TXV 19,900 16.00 13.00 CX35-30A EL180UH045E36A 8260979
14ACXS018-230A TXV 19,900 16.00 13.00 CX35-30A EL180UH045XE36A 8260981
14ACXS018-230A TXV 19,300 14.50 12.20 CX35-30A 8260977
14ACXS018-230A TXV 19,700 15.50 12.50 CX35-30B EL180UH070E36B 8260995
14ACXS018-230A TXV 19,700 15.50 12.50 CX35-30B EL180UH070XE36B 8260986
14ACXS018-230A TXV 18,000 14.50 12.20 CX35-30B EL195UH030XE24B 8606347
14ACXS018-230A TXV 18,000 14.50 12.20 CX35-30B EL195UH045XE24B 8606348
14ACXS018-230A TXV 19,800 16.00 13.00 CX35-30B EL195UH045XE36B 8260988
14ACXS018-230A TXV 19,800 16.00 13.00 CX35-30B EL296UH045XE36B 8260990
14ACXS018-230A TXV 20,400 16.00 13.50 CX35-30B EL296UH045XV36B 8260992
14ACXS018-230A TXV 20,400 16.00 13.50 CX35-30B EL296UH070XV36B 8260993
14ACXS018-230A TXV 20,400 16.00 13.50 CX35-30B SLP98UH070XV36B 8260985
14ACXS018-230A TXV 19,300 14.50 12.20 CX35-30B 8260983
14ACXS024-230A RFC 23,400 14.00 11.50 C33-19 7624485
14ACXS024-230A RFC 23,800 14.00 12.00 C33-25A 7625157
14ACXS024-230A RFC 23,800 14.00 12.00 C33-25B 7625158
14ACXS024-230A RFC 24,000 14.50 12.20 C33-31A 7625160
14ACXS024-230A RFC 24,000 14.50 12.20 C33-31B 7625162
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.