EasyManua.ls Logo

Lennox CBA25UHV-030 User Manual

Lennox CBA25UHV-030
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
NOTICE
A thermostat is not included and must be ordered
separately.
A Lennox communicating thermostat must be used in
communicating applications.
In non-communicating applications, the Lennox
ComfortSense® thermostat may be used, as well as
other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
operation.
Field wiring for both communicating and non-
communicating applications is illustrated in diagrams,
which begin on page 29.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
CBA25UHV
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 30 in this
instruction for information.
Table of Contents
CBA25UHV Unit Dimensions – Upow – inches (mm)...2
Specications and Electrical Data ..................................3
Model Number Identication ...........................................4
Adjusting the BDC3 Blower Control ...............................4
Adjusting the Blower Speed ..........................................4
Blower Data ....................................................................6
Application ....................................................................10
Unit Components ..........................................................10
ECBA25 Electric Heat Data ..........................................12
Heat Section Installation ...............................................17
Conguration Modication ........................................... 19
Brazing Connections ...................................................22
Installing the Condensate Drain ..................................24
Electrical Connections ................................................. 26
Inspecting and Replacing Filters .................................27
Wiring Diagrams ...........................................................28
Professional Maintenance ...........................................30
Check-out Procedures .................................................30
Sequence of Operation ................................................31
Service Literature
UNIT INFORMATION
Corp. 1917-L9
September 20, 2019
CBA25UHV (HFC-410A) SERIES UNITS
General Information
This indoor unit with all-aluminum coil is designed for
installation with optional eld-installed electric heat and a
matched outdoor unit that is charged with HFC-410A re-
frigerant. These units, designed for indoor installation in
multiple positions, are completely assembled for upow
and horizontal right-hand discharge before being shipped
from the factory.
All CBA25UHV air handlers are equipped with a facto-
ry-installed, internally mounted check / expansion valve,
which is suitable for use in HFC-410A applications.
This air handler is compatible with the ComfortSense®
non-communicating thermostat and non-communicating
outdoor units. In addition, this unit has the enhanced ca-
pability of communicating with communicating thermo-
stats and communicating outdoor units using the Lennox
RSBus protocols.
NOTE - For downow or horizontal left-hand air discharge,
certain eld modications are required.
Question and Answer IconNeed help?

Do you have a question about the Lennox CBA25UHV-030 and is the answer not in the manual?

Lennox CBA25UHV-030 Specifications

General IconGeneral
BrandLennox
ModelCBA25UHV-030
CategoryAir Conditioner
LanguageEnglish

Summary

Specifications and Optional Accessories

Specifications and Electrical Data

Lists key technical specifications and electrical data for the unit.

Unit Identification and Blower Control

Blower Speed Settings and Taps

Blower Performance Data (Page 6)

Blower Performance Data (Page 7)

Operating Sequences and Control Jumpers

Single-Stage Unit Operating Sequence

Details the system's operating sequence for single-stage units with thermostat demand.

Two-Stage Unit Operating Sequence

Details the system's operating sequence for two-stage units with thermostat demand.

Electric Heat Data (Page 12)

Electric Heat Data (Page 13)

Electric Heat Data (Page 14)

Electric Heat Data (Page 15)

Electric Heat Data (Page 16)

Heat Section Installation

Heat Element Installation Steps

Provides step-by-step instructions for installing the electric heat element assembly into the air handler.

Electrical Connections and Breaker Covers

Brazing Connections and Refrigerant Lines

Brazing Connections Warnings

Provides critical warnings and precautions related to brazing refrigerant lines.

Refrigerant Connections and Line Set Requirements

Lists refrigerant connection sizes and line set requirements based on model.

Brazing Procedure

Brazing Operations Precautions

Highlights important issues concerning brazing operations and safety.

Brazing Connections Steps

Illustrates the step-by-step process for making brazing connections.

Condensate Drain Installation

Refrigerant Lines and Electrical Connections

Refrigerant Line Installation

Provides guidelines for installing refrigerant lines, emphasizing cleanliness and avoiding kinks.

Filters and Electrical Connections

Wiring Diagrams

Typical Wiring Diagram (Electric Heat)

Shows the typical wiring diagram for the CBA25UHV air handler with electric heat.

Low Voltage Connections

Low Voltage Connections (Variable-Speed Motor)

Illustrates low voltage connections for various thermostat and outdoor unit configurations.

Maintenance and Check-out Procedures

Professional Maintenance

Provides instructions for cleaning the aluminum coil and other maintenance tasks.

Check-out Procedures

Outlines pre-start-up checks, blower, cooling, and electric heat operation checks.

Sequence of Operation

Cooling Operation

Describes the sequence of operation for cooling mode (cooling only or heat pump).

Heating Operation (Electric Heat Only)

Describes the sequence of operation for heating with electric heat only.

Start-up and Performance Checklist

Upflow Configuration Checklist

Checklist for upflow installation start-up and performance verification.

Horizontal Configuration Checklist

Checklist for horizontal installation start-up and performance verification.