Page 52
Cleaning the Burner Assembly (if needed)
1 -   Turn o electrical and gas power supplies to furnace. 
Remove upper and lower furnace access panels.
2 -  Disconnect the 2-pin plug from the gas valve.
3 -  Remove the burner box cover (if equipped).
4 -   Disconnect the gas supply line from the gas valve. 
Remove gas valve/manifold assembly.
5 -   Loosen  clamps  and  remove  combustion air intake 
exible connector (if equipped).
6 -   Mark and disconnect sensor wire from the sensor. 
Disconnect plug from the ignitor at the burner box.
7 -   Remove  four  screws  which  secure  burner  box 
assembly to  vest panel.  Remove burner box  from 
the unit.
8 -   Use the soft brush attachment on a vacuum cleaner 
to  gently  clean  the  face  of  the  burners.  Visually 
inspect the inside of the burners and crossovers for 
any  blockage  caused  by  foreign  matter.  Remove 
any blockage.
9 -   Reinstall the burner box assembly using the existing 
four screws. Make sure that the burners line up in 
the center of the burner ports.
10 -  Reconnect the sensor wire and reconnect the 2-pin 
plug to the ignitor wiring harness.
11 -  Reinstall combustion air intake exible connector (if 
equipped), secure using existing clamps.
12 -  Reinstall  the  gas  valve  manifold  assembly. 
Reconnect  the  gas  supply  line  to  the  gas  valve. 
Reinstall the burner box cover.
13 - Reconnect plug to gas valve.
14 - Replace the blower compartment access panel.
15 -  Refer  to instruction on verifying  gas  and electrical 
connections when re-establishing supplies.
16 -  Follow  lighting  instructions  to  light  and  operate 
furnace for 5 minutes to ensure that heat exchanger 
is  clean  and  dry  and  that  furnace  is  operating 
properly.
17 -  Replace access panel.