EasyManua.ls Logo

Lennox EL296DFV - User Manual

Lennox EL296DFV
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
INSTALLATION
INSTRUCTIONS
EL296DFV
507048-04
06/2020
Supersedes 06/2019
©
2020 Lennox Industries Inc.
Dallas, Texas USA
ELITE
®
SERIES GAS FURNACE
DOWNFLOW AIR DISCHARGE
Contents
Unit Dimensions - inches (mm) ......................................2
EL296DFV Gas Furnace ................................................3
Shipping and Packing List ..............................................3
Safety Information ..........................................................3
Use of Furnace as Construction Heater .........................4
General ...........................................................................5
Combustion, Dilution & Ventilation Air ............................5
Setting Equipment ..........................................................8
Filters ............................................................................12
Duct System .................................................................12
Pipe Fittings Specications...........................................12
Venting Options ............................................................13
Joint Cementing Procedure .......................................... 16
Venting Practices ..........................................................16
Vent Piping Guidelines ................................................18
Gas Piping ...................................................................35
Electrical ......................................................................37
Integrated Control ........................................................47
Blower Motor Performance ..........................................52
Unit Start Up ................................................................56
Gas Pressure Measurement ........................................57
Proper Combustion / High Altitude ..............................58
Heating Sequence of Operation ..................................60
Service .........................................................................61
Program Unit Capacity Size Mode ...............................63
Repair Parts List ...........................................................65
Start-Up Checklist.........................................................67
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
This is a safety alert symbol and should never be
ignored. When you see this symbol on labels or in man-
uals, be alert to the potential for personal injury or death.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer (or
equivalent), service agency or the gas supplier.
NOTICE
A thermostat is not included and must be ordered
separately.
A communicating thermostat must be used in
communicating applications.
In non-communicating applications, the Lennox
ComfortSense
®
7500 thermostat may be used, as well
as other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
operation.
Field wiring for both communicating and non-
communicating applications is illustrated in diagrams,
which begin on Page 39.
CAUTION
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.

Questions and Answers

  • A
    Adam GoodwinAug 21, 2025
    What to do if Lennox EL296DFV Furnace is not leak free?
    • D
      Dr. Eric ScottAug 22, 2025
      If your Lennox Furnace is leaking, ensure that all connections are properly sealed. After sealing the connections, test the system to confirm that the leaks have been resolved.
  • A
    andrewwolfSep 2, 2025
    What to do if Lennox Indoor Fireplace spark igniter will not light pilot?
    • A
      Anthony LynchSep 2, 2025
      If the spark igniter on your Lennox Indoor Fireplace won't light the pilot, start by checking that the electrode wire at the piezo igniter is fully connected. If it is still not working, the piezo igniter may be defective and require replacement. Also, make sure to check for multiple gas shut-offs, gas supply lines, and correct inlet gas pressure as marked on the rating plate. Another possible cause is a plugged pilot orifice that will need to be cleaned or replaced.
  • N
    Nicholas StevensSep 1, 2025
    Why Lennox Indoor Fireplace pilot will not stay lit?
    • S
      Steven GuzmanSep 1, 2025
      If the pilot light won't stay lit on your Lennox Indoor Fireplace, it could be due to a few reasons. First, ensure the thermocouple is firmly connected to the control valve. Second, check that the pilot flame is correctly directed to the top of the thermocouple; ensure the thermocouple is fully inserted into the pilot assembly and adjust the pilot for maximum flame impingement if needed. Finally, the thermocouple itself might be defective and need replacement; it should produce a minimum of 14 MV with the pilot only.
  • T
    Tyler WheelerAug 30, 2025
    How to troubleshoot Lennox Indoor Fireplace spark ignitor that won't light pilot?
    • L
      Laurie HawkinsAug 30, 2025
      If the spark ignitor on your Lennox Indoor Fireplace will not light the pilot after repeated attempts, check for a spark at the electrode and pilot. If there is no spark and it is properly connected, replace the ignitor. You can also use a match to trigger the ignitor mixture cause recommended and pilot. Check the inlet gas pressure to ensure it is within the limits marked on the rating plate. Finally, clean or replace the pilot orifice if it is plugged.
  • T
    Tonya StoneAug 29, 2025
    How to fix Lennox Indoor Fireplace pilot that won't stay lit?
    • S
      samantha52Aug 29, 2025
      If the pilot light on your Lennox Indoor Fireplace will not stay lit after following the lighting instructions, the pilot generator thermocouple may be defective. Check the pilot flame impingement on the thermocouple. Clean and/or adjust the pilot for maximum flame impingement on the thermocouple.
  • P
    Pamela WagnerAug 27, 2025
    What to do if pilot burning, but no gas to burner in Lennox Indoor Fireplace?
    • T
      Tina SimmonsAug 27, 2025
      If the pilot light is burning but no gas is going to the burner in your Lennox Indoor Fireplace, even with the valve knob and wall switch 'ON', check the wall switch and wires for proper connections. Also, the thermopile may not be generating sufficient millivoltage, so check the thermopile terminals with a millivolt meter. Finally, check the burner orifice for any blockage and remove it.
  • A
    Ashley RoachAug 26, 2025
    What to do if my Lennox Indoor Fireplace burners come 'ON' but go 'OFF'?
    • L
      Lisa WilliamsAug 26, 2025
      If the burners on your Lennox Indoor Fireplace turn on but then turn off, check the main burner orifice(s) for any blockage. Clean or replace the orifice if necessary. Also, check the vent system for obstructions.
  • M
    Melinda TurnerAug 25, 2025
    Why does my Lennox Indoor Fireplace pilot keep going out?
    • V
      Vernon GriffinAug 25, 2025
      Frequent pilot/burner outages in your Lennox Indoor Fireplace may occur if the pilot valve flame is too low or too high, causing the pilot safety to drop out. Clean and/or adjust the pilot flame for maximum flame impingement on the thermocouple.
  • K
    Kyle LambertAug 23, 2025
    What to do if my Lennox Indoor Fireplace burner will not light?
    • M
      morrisalisonAug 23, 2025
      If your Lennox Indoor Fireplace burner will not light, there may be a faulty valve system or a defective 'OFF/ON' wall switch. Disconnect the two black wires from the wire nuts and check for continuity with a multimeter.