EasyManua.ls Logo

Lennox EL296UH045XE36B - Dual Fuel Single Stage Heat Pump Wiring; Dual Fuel Two Stage Heat Pump Wiring

Lennox EL296UH045XE36B
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 58
TABLE 28
EL296 Field Wiring Applications (Continued)
Thermostat
DIP Switch Settings and On-Board Links (figure 4)
Wiring Connections
DIP Switch 1
Thermostat
Heating
Stages
On Board Links Must Be Cut To Select
System Options
Dual Fuel
Single Stage
Heat Pump
ComfortSense
7000 L7724U
thermostat w/
dual fuel capa
bilities
Capable of 2
stage gas heat
control
OFF
CUT ON-BOARD LINK
W951
HEAT
PUMP
DEHUM
L7724U
T'STAT
FURNACE
TERM. STRIP
HEAT PUMP
67M41*
Y
H
L
Y2
D
B
L
Y2
Dual Fuel
Two Stage
Heat Pump
ComfortSense
7000 L7724U
thermostat w/
dual fuel capa
bilities
Capable of 2
stage gas heat
control
OFF
CUT ON-BOARD LINK
W951
HEAT
PUMP
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
DEHUM
FURNACE
TERM. STRIP
HEAT PUMP
out blue
67M41*
H
L
Y2
D
B
L
Y2
L7724U
T'STAT
* Connect W1 to W1 ONLY if using defrost tempering kit 67M41
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the EL296
integrated control.

Table of Contents