Page 43
Ignition Control  103130-XX Diagnostic Codes
Code Diagnostic Codes/Status of Equipment Action Required to Clear and Recover
E406 LSOM - Compressor open start circuit. Required amount of current is not passing through Start cur-
rent  transformer.  Clears  the  error  after  current  is  sensed  in 
START sensor, or after power reset.
E407 LSOM - Compressor open run circuit. Required amount of current is not passing through Run current 
transformer.  Clears  the  error  after current  is  sensed  in  RUN 
sensor, or 1 normal compressor run cycle, or after power reset.
E408 LSOM - Compressor contactor is welded. Compressor runs continuously. Clears the error after 1 normal 
compressor run cycle or after power reset.
E409 LSOM - Compressor low voltage. Secondary  voltage  is  below  18VAC. After  10  minutes,  oper-
ation is discontinued. Clears the code after voltage is higher 
than 20 VAC for 2 seconds or after power reset.