TABLE 23
G61MPV−60C−110 and G61MPV−60C−111 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Bottom; both sides; or bottom and one side.
ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage HEAT" Speed Second Stage COOL" Speed
1 2 3 4 1 2 3 4
cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s
+
1505 710 1710 805 1915 905 2130 1005 1625 770 1745 825 1990 940 2210 1045
NORM 1370 645 1565 740 1765 835 1945 920 1465 690 1580 745 1790 845 1995 940
 1205
570 1380 650 1565 740 1740 820 1290 610 1405 660 1605 760 1790 845
ADJUST"
Switch
Positions
First Stage HEAT" Speed First Stage COOL" Speed
1 2 3 4 1 2 3 4
cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s
+
1370 645 1570 740 1760 830 1945 920 945 445 1020 480 1160 545 1300 615
NORM 1235 585 1420 670 1600 755 1780 840 840 395 910 430 1055 500 1180 555
1105 525 1250 590 1420 670 1580 745 740 350 800 380 920 435 1045 495
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage
 HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s).
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 463 cfm (220 L/s).
TABLE 24
G61MPV−60C−110 and G61MPV−60C−111 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Single side return air − Bold volumes require field−fabricated transition to accommodate
20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter.
ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage HEAT" Speed Second Stage COOL" Speed
1 2 3 4 1 2 3 4
cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s
+
1485 700 1675 790 1870 885 2080 980 1585 750 1700 800 1905 900 2135 1005
NORM 1350 637 1525 720 1725 815 1895 895 1435 680 1535 725 1740 820 1930 910
 1175
555 1335 630 1505 710 1670 790 1280 605 1385 655 1570 740 1755 830
ADJUST"
Switch
Positions
First Stage HEAT" Speed First Stage COOL" Speed
1 2 3 4 1 2 3 4
cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s
+
1325 625 1505 710 1695 800 1870 885 935 440 1025 485 1155 545 1285 605
NORM 1195 565 1365 645 1550 730 1720 810 840 395 915 430 1050 495 1175 555
1080 510 1205 570 1365 645 1530 720 750 355 800 380 925 435 1050 495
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage
 HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s).
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 463 cfm (220 L/s).