Page 33
TABLE 21
G61MPVT−60D−135 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Bottom.
ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage HEAT" Speed Second Stage COOL" Speed
1 2 3 4 1 2 3 4
cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s
+
1505 710 1705 805 1900 900 2110 995 1615 760 1730 815 1945 920 2190 1035
NORM 1365 645 1550 730 1740 820 1920 905 1455 685 1580 745 1780 840 1985 935
1225
580 1380 650 1545 730 1720 810 1305 615 1400 660 1600 755 1780 840
ADJUST"
Switch
Positions
First Stage HEAT" Speed First Stage COOL" Speed
1 2 3 4 1 2 3 4
cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s
+
1385 655 1570 740 1760 830 1930 910 1135 535 1205 570 1365 645 1540 725
NORM 1250 590 1425 670 1595 755 1775 835 1025 485 1105 520 1235 580 1390 655
1135 535 1265 595 1430 675 1585 750 915 430 985 465 1115 525 1235 585
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage
HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s).