WARNING
Improper installation, adjustment, alteration, ser
vice or maintenance can cause property damage,
personal injury or loss of life. Installation and ser
vice must be performed by a licensed professional
HVAC installer or equivalent, service agency, or the
gas supplier
Table Of Contents
Dimensions Page 2.................................
Parts Arrangements Page 3.........................
Shipping and Packing List Page 4....................
General Page 4....................................
Requirements Page 4...............................
Unit Support Page 5................................
Duct Connection Page 6............................
Rigging Unit For Lifting Page 6.......................
Horizontal Air Discharge Page 6......................
Condensate Drains Page 7..........................
Gas Piping Page 8.................................
Pressure Test Gas Piping Page 9.....................
High Altitude Derate Page 10.........................
Download Mobile Service App Page 10.................
Electrical Connections Page 10.......................
Blower Operation and Adjustments Page 13............
Cooling Start-Up Page 21............................
Prognostic & Diagnostic Sensors Page 30..............
Cooling Operation Page 33...........................
INSTALLATION
INSTRUCTIONS
LGT/LCT036, 048,
060, 072
3, 4, 5 and 6 Ton
GAS AND COOLING PACKAGED UNITS
508286-01
7/2022
WARNING
To prevent serious injury or death:
1- Lock-out/tag-out before performing maintenance.
2- If system power is required (e.g., smoke detector mainte
nance), disable power to blower, remove fan belt where
applicable, and ensure all controllers and thermostats are
set to the “OFF” position before
performing maintenance.
3- Always keep hands, hair, clothing, jewelry, tools, etc.,
away from moving part
s.
Gas Heat Start-Up Page 34...........................
Heating Operation and Adjustments Page 35............
Electric Heat Start-Up Page 35........................
Hot Gas Reheat Startup Page 36......................
Service Page 38....................................
Factory Unit Controller Settings Page 49...............
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
Use this QR code to download the mobile service app. Follow the prompts
to pair the app with the unit control system and configure the unit. Refer to the
“Download Mobile App” section in this manual and the Setup Guide provided
with this unit. The QR code is also available in the unit control area.
The app can be downloaded from the appropriate iOS or Android store.
Look for the following icon.
Attention!
Question and Answer IconNeed help?

Do you have a question about the Lennox LCT048 and is the answer not in the manual?

Lennox LCT048 Specifications

General IconGeneral
Cooling Capacity48, 000 BTU/h
RefrigerantR-410A
Operating Voltage208/230V
Phase1
Sound Level (Outdoor Unit)76 dB

Summary

DIMENSIONS

LGT036, 048, 060, & 072 PARTS ARRANGEMENT

LCT036, 048, 060, & 072 PARTS ARRANGEMENT

Duct Connection

Rigging Unit For Lifting

Condensate Drains

Connect Gas Piping (Gas Units)

Pressure Test Gas Piping (Gas Units)

Electrical Connections - Power Supply

Electrical Connections - Control Wiring

Blower Operation and Adjustments

B-Determining Unit CFM

Procedure to measure and determine the unit's airflow volume (CFM).

C-Adjusting Unit CFM

BLOWER PARAMETER SETTINGS

BLOWER DATA

Cooling Start-Up

A-Operation

Steps to initiate full load cooling operation using the mobile service app.

B-Refrigerant Charge and Check - All-Aluminum Coil

Procedure for checking and adjusting refrigerant charge for optimal performance.

C-Compressor Controls

3- Diagnostics Sensors (RT46, RT48)

Information on thermistors used for temperature feedback and protection.

Diagnostic Sensors

Cooling Operation

A-Two-Stage Thermostat

Cooling operation modes for two-stage thermostats with/without economizer.

Gas Heat Start-Up (Gas Units)

FOR YOUR SAFETY READ BEFORE LIGHTING

Critical safety warnings and instructions before lighting the unit.

A-Placing Unit In Operation

Step-by-step procedure for putting the unit into operation.

Heating Operation and Adjustments (Gas Units)

Electric Heat Start-Up (LCT Units)

SCR Electric Heat Controller (LCT Units)

Hot Gas Reheat Start-Up And Operation

General

Overview of hot gas reheat for dehumidification mode.

Check-Out

Procedure to test and verify hot gas reheat operation.

Service

D-Combustion Air Inducer (Gas Units)

E-Flue Box (Gas Units)

F-Evaporator Coil

G-Condenser Coil

H-Supply Air Blower Wheel

L-Replacement Fuses

Factory Unit Controller Settings

Units With BACnet Settings

Menu paths for configuring BACnet settings via the mobile service app.

Units With Room Sensor, CPCLSE Gateway Settings

Menu paths for configuring gateway settings via the mobile service app.

Units With LonTalk Settings

Menu paths for configuring LonTalk settings via the mobile service app.

Units With Hot Gas Reheat

Parameters for configuring hot gas reheat options and timeouts.