EasyManuals Logo

Lennox LRP14HP30 User Manual

Lennox LRP14HP30
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Page 24
Blower Data – LRP14AC
Model
No.
Blower Tap
Air Volume (cfm) at Various External Static Pressures - in. w.g.
0.1 0.2 0.30.4 0.50.6 0.
70
.8
LRP14AC24
Tap 1 (Fan Only) 610 560 525485 430- - -- -
--
- -
Tap 2 (Low Cooling) 820 795 760720 690650 61
55
75
Tap 3 (High Cooling) 950 920 880850 820800 76
07
20
¹ Tap 4 (Low Electric Heat) 820 795 760720 - - -- - -- -
--
- -
¹ Tap 5 (High Electric Heat) - - -- - -- - -- - -820 800760 720
LRP14AC30
Tap 1 (Fan Only) 850 820 780745 710680 63
05
90
Tap 2 (Low Cooling) 1040 1000 970935 900875 84
58
15
Tap 3 (High Cooling) 1175 1145 1115 1080 1050 1015 99
09
45
¹ Tap 4 (Low Electric Heat) 1040 1000 970935 - - -- - -- -
--
- -
¹ Tap 5 (High Electric Heat) - - -- - -- - -- - -1050 1015 99
09
45
LRP14AC36
Tap 1 (Fan Only) 850 800 750700 645600 55
04
80
Tap 2 (Low Cooling) 1245 1210 1175 1140 1100 1065 1025 975
Tap 3 (High Cooling) 1400 1370 1335 1300 1265 1220 1180 1150
¹ Tap 4 (Low Electric Heat) 1265 1210 1175 1160 - - -- - -- -
--
- -
¹ Tap 5 (High Electric Heat) - - -- - -- - -- - -1265 1220 1180 1150
LRP14AC42
Tap 1 (Fan Only) 800 720 640550 475390 31
0-
- -
Tap 2 (Low Cooling) 1470 1410 1360 1300 1260 1210 1155 1095
Tap 3 (High Cooling) 1700 1650 1610 1575 1540 1480 1430 1390
¹ Tap 4 (Low Electric Heat) 1630 1410 1360 1300 - - -- - -- -
--
- -
¹ Tap 5 (High Electric Heat) - - -- - -- - -- - -1540 1480 1430 1390
LRP14AC48
Tap 1 (Fan Only) 1145 1075 1000 930850 790740 670
Tap 2 (Low Cooling) 1675 1630 1600 1540 1490 1440 1390 1300
Tap 3 (High Cooling) 1800 1770 1715 1690 1640 1610 1565 1500
¹ Tap 4 (Low Electric Heat) 1675 1630 1600 1560 - - -- - -- -
--
- -
¹ Tap 5 (High Electric Heat) - - -- - -- - -- - -1640 1610 1565 1500
LRP14AC60
Tap 1 (Fan Only) 1400 1320 1260 1200 1120 1060 98
09
00
Tap 2 (Low Cooling) 1920 1870 1820 1770 1720 1670 1450 1360
Tap 3 (High Cooling) 2240 2200 2140 2100 2060 2020 1980 1950
¹ Tap 4 (Low Electric Heat) 1920 1870 1820 1770 - - -- - -- -
--
- -
¹ Tap 5 (High Electric Heat) - - -- - -- - -- - -2060 2020 1980 1950
1
Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox LRP14HP30 and is the answer not in the manual?

Lennox LRP14HP30 Specifications

General IconGeneral
BrandLennox
ModelLRP14HP30
CategoryFurnace
LanguageEnglish

Related product manuals