EasyManua.ls Logo

Lennox MCA012S4S-1P

Lennox MCA012S4S-1P
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
MINI-SPLIT SYSTEMS SERVICE MANUAL
MCA Series Unit Information
CORP1907-L5
11/2020
Supersedes 8/2019
Table of Contents
1. Indoor Units ................................................3
1.1. ModelNumberIdentication ................................... 3
1.2. IndoorUnitSpecications ....................................... 3
1.3. Indoor Unit Dimensions .......................................... 4
1.4. IndoorUnitClearances ........................................... 5
1.5. IndoorUnitWallMounts ......................................... 5
2. Indoor/Outdoor Matches ...........................6
3. Air Throw Data ...........................................6
4. Power and Communication Wiring for
Systems .....................................................7
4.1. Overview ................................................................. 7
4.2. WireGauge............................................................. 7
4.3. TerminalConnections ............................................. 8
5. Indoor Unit Diagrams ................................8
6. Wireless Remote ...................................... 10
6.1. Requirements ....................................................... 10
6.2. RemoteControlSpecications ............................. 10
6.3. FunctionButtons ................................................... 11
6.4. Display .................................................................. 12
6.5. Operations ............................................................ 12
6.5.1. Start/StopOperation.............................. 12
6.5.2. Select Fahrenheit or Celsius ............... 12
6.5.3. Cool/Fan mode ..................................... 12
6.5.4. DryMode ................................................ 12
6.5.5. TimerOperation ..................................... 12
6.5.6. TimerONOperation ............................... 12
6.5.7. TimerOFFOperation ............................. 13
6.5.8. ModifyTimerON/OFFsettings ............... 13
7. Connection to Centralized Controller ....13
7.1. SetIndoorUnitAddressforCentralizedControl
(UsedwithVRFOnly) ........................................... 13
7.2. IndoorUnitConnectionPointsforCentralized
Controller .............................................................. 14
7.3. DryModeOperation-IndoorUnits ....................... 14
7.3.1. Procedure ............................................... 14
7.3.2. DryModeOperationSequence .............. 14
7.4. TestRun-IndoorUnits ......................................... 14
7.4.1. TestRunInstructions .............................. 14
7.4.2. BeforeTestRun ...................................... 14
7.5. Double-CheckPipeConnections .......................... 15
7.6. AmbientTemperatureisBelow63°F(17°C) ......... 15
8. Single Zone Outdoor Units .....................16
8.1. ModelNumberIdentication ................................. 16
8.2. Specications........................................................ 16
8.3. CoolingCapacity................................................... 17
8.3.1. -009(208/230V) .................................... 17
8.3.2. -012(115V) ............................................ 18
8.3.3. -012(208/230V) .................................... 18
MCA Single Zone Air
Conditioning Outdoor Unit
MCWA Wall Mount Single Zone
Air Conditioning Indoor Unit
Please refer to Corp1908-L5 for indoor and outdoor unit error codes and component diagnostics.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lennox MCA012S4S-1P and is the answer not in the manual?

Lennox MCA012S4S-1P Specifications

General IconGeneral
BrandLennox
ModelMCA012S4S-1P
CategoryAir Conditioner
LanguageEnglish

Summary

Indoor Units

Indoor Unit Specifications

Provides technical specifications for various indoor unit models.

Power and Communication Wiring for Systems

Connection to Centralized Controller

Test Run - Indoor Units

Provides a checklist and instructions for performing a system test run after installation.

Single Zone Outdoor Units

Model Number Identification

Identifies model number components for outdoor units.

Specifications

Provides technical specifications for various outdoor unit models.

Refrigeration Pipe Work

Installation Requirements

Gas Leak Check with Soap Water

Explains the procedure for checking pipe connections for refrigerant leaks.

Air Purging using a Vacuum Pump

Describes the process of removing air and moisture from the refrigerant system.

Related product manuals