EasyManua.ls Logo

Lennox Merit ML14XC1-030-230 User Manual

Lennox Merit ML14XC1-030-230
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
7/2012 506945-01
*2P72012* *P506945-01*
Page 1
E2013 Lennox Industries Inc.
Dallas, Texas, USA
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
WARNING
The State of California has determined that this product
may contain or produce a chemical or chemicals, in very
low doses, which may cause serious illness or death. It
may also cause cancer, birth defects, or reproductive
harm.
GENERAL
This 13ACX outdoor unit is designed for use with HFC-410A
refrigerant only. This unit must be installed with an approved
indoor unit. See the Lennox 13ACX Product Specifications
bulletin (EHB) for approved indoor component match ups.
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.
INSTALLATION
INSTRUCTIONS
Merit
®
Series 13ACX Units
AIR CONDITIONER
506945-01
5/2013
Supersedes 7/2012
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause personal injury, loss of life, or
damage to property.
Installation and service must be performed by a licensed
professional installer (or equivalent) or a service agency.
CAUTION
Before attempting to perform any service or maintenance,
turn the electrical power to unit OFF at disconnect switch.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take care
while handling this equipment.
STEP 1 -- SETTING THE UNIT -- Clearances
6 (152)
36 (914)
12 (305)
30 (762)
LINE SET
CONNECTIONS
24 (610)
LINE SET
CONNECTIONS
ACCESS
PANEL
48 (1219)
MINIMUM CLEARANCE BETWEEN TWO UNITS
CLEARANCE ON ALL SIDES — INCHES (MILLIMETERS)
MINIMUM CLEARANCE
ABOVE UNIT
NOTES:
S Clearance to one of the other three
sides must be 36 inches (914mm).
S Clearance to one of the remaining
two sides may be 12 inches
(305mm) and the final side may be
6 inches (152mm).
FIGURE 1
Litho U.S.A.
Question and Answer IconNeed help?

Do you have a question about the Lennox Merit ML14XC1-030-230 and is the answer not in the manual?

Lennox Merit ML14XC1-030-230 Specifications

General IconGeneral
BrandLennox
ModelMerit ML14XC1-030-230
CategoryAir Conditioner
LanguageEnglish

Summary

Setting the Unit - Clearances

Clearances on All Sides

Specifies minimum clearances required for all sides of the unit.

Minimum Clearance Above Unit

Details the required minimum clearance above the outdoor unit.

Minimum Clearance Between Two Units

Outlines minimum clearance requirements between multiple outdoor units.

Setting the Unit - Unit Placement

Unit Placement

Instructions and warnings regarding the proper placement of the outdoor unit.

Slab Mounting

Guidance on mounting the unit level or with a slight slope on a slab.

Line Set Installation

Line Set Isolation

Illustrates examples of proper refrigerant line set isolation techniques.

Refrigerant Line Set Transition From Vertical To Horizontal

Shows how to transition refrigerant lines from vertical to horizontal runs.

Refrigerant Line Set Installing Vertical Runs

Details the installation of refrigerant line sets for vertical runs.

Refrigerant Line Set Installing Horizontal Runs

Explains installation methods for horizontal refrigerant line runs.

Refrigerant Piping - Flushing Existing Line Set and Indoor Coil

Flushing Existing Line Set and Indoor Coil

Procedure for flushing the existing line set and indoor coil.

Liquid Line Filter Drier Installation

Instructions for field installation of the liquid line filter drier.

Refrigerant Piping - Removing Existing Indoor Metering Device

Typical Existing Fixed Orifice Removal Procedure

Steps for removing a fixed orifice metering device from the indoor coil.

Typical Existing Expansion Valve Removal Procedure

Steps for removing an expansion valve metering device from the indoor coil.

Flushing Line Set

Procedure for flushing the refrigerant line set and indoor coil.

Refrigerant Piping - Brazing Procedures

Cut and Debur

Instructions on cutting and deburring refrigerant line ends.

Cap and Core Removal

Procedure for removing service valve caps and cores.

Attach Manifold Gauge Set

How to connect the manifold gauge set for brazing operations.

Refrigerant Piping - Brazing Procedures (Continued)

Wrap Service Valves

How to wrap service valves with water-saturated cloths during brazing.

Flow Nitrogen

Procedure for flowing nitrogen through the line set during brazing.

Braze Line Set

Steps for brazing the refrigerant line set to the service valves.

Preparation for Next Step

Tasks to perform after brazing connections are complete.

Refrigerant Piping - Installing Indoor Expansion Valve

Indoor Expansion Valve Installation

Steps for installing the expansion valve unit, internal or external to the coil.

Sensing Bulb Installation

Guidance on installing the sensing bulb correctly on the vapor line.

Equalizer Line Installation

Instructions for connecting the equalizer line to the vapor line.

Leak Test and Evacuation

Connect Gauge Set

How to connect the manifold gauge set for leak testing.

Test for Leaks

Procedure for testing the system for leaks using nitrogen.

Leak Test and Evacuation (Continued)

Connect Gauge Set

Connecting the manifold gauge set for evacuation.

Evacuate the System

Steps to evacuate the refrigerant lines and indoor unit to the specified vacuum level.

Electrical - Circuit Sizing and Wire Routing

Size Circuit and Install Service Disconnect Switch

How to size electrical circuits and install the service disconnect switch.

Install Thermostat

Guidance on the proper location and installation of the room thermostat.

Electrical - High Voltage and Field Control Wiring

Routing High Voltage, Ground and Control Wiring

How to route high voltage, ground, and control wiring within the unit.

Unit Start-Up

Procedures for starting up the unit after installation and checks.

Torque Requirements

Parts

Table listing parts and their recommended torque values.

Using Manifold Gauge Set

Instructions on using the manifold gauge set for system checks.

Checking and Adding System Refrigerant

Homeowners Information

Information for homeowners regarding unit maintenance and operation.

Outdoor Coil

Guidance on proper maintenance of the outdoor unit's coil.

Routine Maintenance

General advice for maintaining peak system performance.

Thermostat Operation

Instructions on how to operate the thermostat.

Preservice Check

Checks to perform before calling for service.

Start-Up and Performance Checklist

Start Up Checks

Key checks to perform during unit start-up.

Cooling Mode

Parameters to check for the unit in cooling mode.

System Refrigerant Charge

Information on checking and verifying system refrigerant charge.