ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 14
AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-041-230 TXV 37800 16 13 CH35-48C SL280UH090V60C 9144827
ML14XC1-041-230 TXV 38000 16 13 CH35-48C SL280UH110V60C 9144828
ML14XC1-041-230 TXV 37800 16 13 CH35-48C SLP98UH090XV36C 9144829
ML14XC1-041-230 TXV 38000 16 13 CH35-48C SLP98UH090XV48C 9144830
ML14XC1-041-230 TXV 37800 16 13 CH35-48C SLP98UH090XV60C 9144831
ML14XC1-041-230 TXV 38000 16 13 CH35-48C SLP98UH110XV60C 9144832
ML14XC1-041-230 TXV 37600 15.5 12.5 CH35-48C 9144833
ML14XC1-041-230 TXV 39000 17 13.5 CH35-51C EL180UH090E60C 9144834
ML14XC1-041-230 TXV 38500 17 13.5 CH35-51C EL180UH110E60C 9144835
ML14XC1-041-230 TXV 38500 16 13 CH35-51C EL195UH090XE48C 9144836
ML14XC1-041-230 TXV 39000 16 13 CH35-51C EL195UH110XE60C 9144837
ML14XC1-041-230 TXV 38500 16 13 CH35-51C EL296UH090XE48C 9144838
ML14XC1-041-230 TXV 39000 16 13 CH35-51C EL296UH110XE60C 9144839
ML14XC1-041-230 TXV 39000 16 13 CH35-51C EL296UH110XV48C 9144840
ML14XC1-041-230 TXV 38500 16 13 CH35-51C SLP98UH090XV36C 9144841
ML14XC1-041-230 TXV 38500 16 13 CH35-51C SLP98UH090XV48C 9144842
ML14XC1-041-230 TXV 39000 16 13 CH35-51C SLP98UH090XV60C 9144843
ML14XC1-041-230 TXV 38500 16 13 CH35-51C SLP98UH110XV60C 9144844
ML14XC1-041-230 TXV 38500 15.5 12.5 CH35-51C 9144845
ML14XC1-041-230 TXV 37600 16 13 CR33-50/60 EL195DF090XE48C 9144846
ML14XC1-041-230 TXV 37400 16 13 CR33-50/60 EL195DF110XE60C 9144847
ML14XC1-041-230 TXV 37600 16 13 CR33-50/60 EL296DF090XE48C 9144848
ML14XC1-041-230 TXV 37400 16 13 CR33-50/60 EL296DF090XV60C 9144849
ML14XC1-041-230 TXV 37400 16 13 CR33-50/60 EL296DF110XE60C 9144850
ML14XC1-041-230 TXV 37400 16 13 CR33-50/60 EL296DF110XV60C 9144851
ML14XC1-041-230 TXV 37800 16 13 CR33-50/60 SL280DF090V60C 9144852
ML14XC1-041-230 TXV 38000 16 13.5 CR33-50/60 SL280DF110V60C 9144853
ML14XC1-041-230 TXV 38000 16 13 CX35-36B EL180UH090E48B 9144924
ML14XC1-041-230 TXV 38000 16 13 CX35-36B EL180UH090XE48B 9144925
ML14XC1-041-230 TXV 37600 16 13 CX35-36B EL296UH045XV36B 9973353
ML14XC1-041-230 TXV 37800 16 13 CX35-36B SL280UH090V36B 9144927
ML14XC1-041-230 TXV 38000 16 13 CX35-36B SL280UH090V48B 9144928
ML14XC1-041-230 TXV 37600 15.5 13 CX35-36B SLP98UH070XV36B 10040418
ML14XC1-041-230 TXV 37400 15.5 12.5 CX35-36B 9144930
ML14XC1-041-230 TXV 38500 16 13 CX35-48B EL180UH090E48B 9144931
ML14XC1-041-230 TXV 38500 16 13 CX35-48B EL180UH090XE48B 9144932
ML14XC1-041-230 TXV 37800 16 13 CX35-48B EL296UH045XV36B 9973354
ML14XC1-041-230 TXV 38000 16 13 CX35-48B SL280UH090V36B 9144934
ML14XC1-041-230 TXV 38500 16 13 CX35-48B SL280UH090V48B 9144935
ML14XC1-041-230 TXV 37800 16 13 CX35-48B SLP98UH070XV36B 10040419
ML14XC1-041-230 TXV 37800 15.5 12.5 CX35-48B 9144937
ML14XC1-041-230 TXV 38500 17 13.5 CX35-48C EL180UH090E60C 9144938
ML14XC1-041-230 TXV 38500 16 13.5 CX35-48C EL180UH110E60C 9144939
ML14XC1-041-230 TXV 38500 16 13.5 CX35-48C EL180UH110XE60C 9144940
ML14XC1-041-230 TXV 38000 16 13 CX35-48C EL195UH090XE48C 9144941
ML14XC1-041-230 TXV 37800 17 13.5 CX35-48C EL195UH110XE60C 9144942
ML14XC1-041-230 TXV 38000 16 13 CX35-48C EL296UH090XE48C 9144943
ML14XC1-041-230 TXV 38000 16 13 CX35-48C EL296UH090XV36C 9144944
ML14XC1-041-230 TXV 38000 16 13 CX35-48C EL296UH090XV48C 9144945
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MERIT ML14XC1 and is the answer not in the manual?

Lennox MERIT ML14XC1 Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
Cooling Capacity (BTU/h)18, 000 - 60, 000
Operating Voltage (VAC)208/230
Unit Weight (lbs)Varies by model
Dimensions (H x W x D, inches)Varies by model
Cooling Capacity1.5 to 5 tons
Warranty5-Year Limited Warranty on covered components