ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 15
AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-041-230 TXV 38000 16 13 CX35-48C EL296UH090XV60C 9144946
ML14XC1-041-230 TXV 37800 17 13.5 CX35-48C EL296UH110XE60C 9144947
ML14XC1-041-230 TXV 38500 16 13 CX35-48C EL296UH110XV48C 9144948
ML14XC1-041-230 TXV 38500 16 13.5 CX35-48C EL296UH110XV60C 9144949
ML14XC1-041-230 TXV 38500 17 13.5 CX35-48C SL280UH090V60C 9144950
ML14XC1-041-230 TXV 38500 17 13.5 CX35-48C SL280UH090XV60C 9144951
ML14XC1-041-230 TXV 38000 16 13 CX35-48C SL280UH110V60C 9144952
ML14XC1-041-230 TXV 38000 16 13 CX35-48C SL280UH110XV60C 9144953
ML14XC1-041-230 TXV 38000 16 13 CX35-48C SLP98UH090XV36C 9144954
ML14XC1-041-230 TXV 38000 16 13 CX35-48C SLP98UH090XV48C 9144955
ML14XC1-041-230 TXV 38000 16 13 CX35-48C SLP98UH090XV60C 9144956
ML14XC1-041-230 TXV 38500 16 13.5 CX35-48C SLP98UH110XV60C 9144957
ML14XC1-041-230 TXV 37800 15.5 12.5 CX35-48C 9144958
ML14XC1-041-230 TXV 39000 17 13.5 CX35-49C EL180UH090E60C 9144959
ML14XC1-041-230 TXV 38500 17 13.5 CX35-49C EL180UH110E60C 9144960
ML14XC1-041-230 TXV 38500 17 13.5 CX35-49C EL180UH110XE60C 9144961
ML14XC1-041-230 TXV 38500 16 13.5 CX35-49C EL195UH090XE48C 9144962
ML14XC1-041-230 TXV 39000 16 13 CX35-49C EL195UH110XE60C 9144963
ML14XC1-041-230 TXV 38500 16 13.5 CX35-49C EL296UH090XE48C 9144965
ML14XC1-041-230 TXV 38500 16 13 CX35-49C EL296UH090XV36C 9144964
ML14XC1-041-230 TXV 38500 16 13 CX35-49C EL296UH090XV48C 9144966
ML14XC1-041-230 TXV 39000 16 13 CX35-49C EL296UH110XE60C 9144968
ML14XC1-041-230 TXV 38500 16 13 CX35-49C EL296UH110XV48C 9144967
ML14XC1-041-230 TXV 39000 16 13.5 CX35-49C EL296UH110XV60C 9144969
ML14XC1-041-230 TXV 39000 17 13.5 CX35-49C SL280UH090V60C 9144970
ML14XC1-041-230 TXV 38500 16 13 CX35-49C SL280UH110V60C 9144971
ML14XC1-041-230 TXV 38500 16 13 CX35-49C SLP98UH090XV36C 9144972
ML14XC1-041-230 TXV 38500 16 13 CX35-49C SLP98UH090XV48C 9144973
ML14XC1-041-230 TXV 39000 16 13 CX35-49C SLP98UH090XV60C 9144974
ML14XC1-041-230 TXV 39000 16 13.5 CX35-49C SLP98UH110XV60C 9144975
ML14XC1-041-230 TXV 38000 15.5 12.5 CX35-49C 9144976
ML14XC1-041-230 TXV 38000 16 13 CX35-50/60C EL180UH090E60C 9144983
ML14XC1-041-230 TXV 37800 16 13 CX35-50/60C EL180UH110E60C 9144984
ML14XC1-041-230 TXV 37800 16 13 CX35-50/60C EL180UH110XE60C 9144985
ML14XC1-041-230 TXV 37600 16 13 CX35-50/60C EL195UH090XE48C 9144986
ML14XC1-041-230 TXV 37400 16 13 CX35-50/60C EL195UH110XE60C 9144987
ML14XC1-041-230 TXV 37600 16 13 CX35-50/60C EL296UH090XE48C 9144988
ML14XC1-041-230 TXV 37400 16 13 CX35-50/60C EL296UH110XE60C 9144989
ML14XC1-041-230 TXV 38000 16 13 CX35-50/60C EL296UH110XV48C 9144977
ML14XC1-041-230 TXV 37600 16 13 CX35-50/60C SLP98UH090XV36C 9144978
ML14XC1-041-230 TXV 37800 16 13 CX35-50/60C SLP98UH090XV48C 9144979
ML14XC1-041-230 TXV 37600 16 13 CX35-50/60C SLP98UH090XV60C 9144980
ML14XC1-041-230 TXV 38000 16 13 CX35-50/60C SLP98UH110XV60C 9144981
ML14XC1-041-230 TXV 37600 15.1 12.5 CX35-50/60C 9144982
ML14XC1-041-230 TXV 39500 17 13.5 CX35-60C EL180UH090E60C 9144991
ML14XC1-041-230 TXV 39000 17 13.5 CX35-60C EL180UH110E60C 9144992
ML14XC1-041-230 TXV 39000 17 13.5 CX35-60C EL180UH110XE60C 9144993
ML14XC1-041-230 TXV 39000 17 13.5 CX35-60C EL195UH090XE48C 9144994
ML14XC1-041-230 TXV 39500 17 13.5 CX35-60C EL195UH110XE60C 9144995
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MERIT ML14XC1 and is the answer not in the manual?

Lennox MERIT ML14XC1 Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
Cooling Capacity (BTU/h)18, 000 - 60, 000
Operating Voltage (VAC)208/230
Unit Weight (lbs)Varies by model
Dimensions (H x W x D, inches)Varies by model
Cooling Capacity1.5 to 5 tons
Warranty5-Year Limited Warranty on covered components