EasyManuals Logo

Lennox MERIT ML14XC1 User Manual

Lennox MERIT ML14XC1
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 16
AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-041-230 TXV 39000 17 13.5 CX35-60C EL296UH090XE48C 9144996
ML14XC1-041-230 TXV 39000 16 13.5 CX35-60C EL296UH090XV36C 9144997
ML14XC1-041-230 TXV 39000 17 13.5 CX35-60C EL296UH090XV48C 9144998
ML14XC1-041-230 TXV 39500 16 13.5 CX35-60C EL296UH090XV60C 9144999
ML14XC1-041-230 TXV 39500 17 13.5 CX35-60C EL296UH110XE60C 9145000
ML14XC1-041-230 TXV 39500 17 13.5 CX35-60C EL296UH110XV60C 9145001
ML14XC1-041-230 TXV 39500 17 13.5 CX35-60C SL280UH090V60C 9145002
ML14XC1-041-230 TXV 39000 17 13.5 CX35-60C SL280UH110V60C 9145003
ML14XC1-041-230 TXV 39000 16 13.5 CX35-60C SLP98UH090XV36C 9145004
ML14XC1-041-230 TXV 39000 17 13.5 CX35-60C SLP98UH090XV48C 9145005
ML14XC1-041-230 TXV 39500 16 13.5 CX35-60C SLP98UH090XV60C 9145006
ML14XC1-041-230 TXV 39500 17 13.5 CX35-60C SLP98UH110XV60C 9145007
ML14XC1-041-230 TXV 38500 15.5 13 CX35-60C 9144990
ML14XC1-041-230 TXV 38000 15.5 12.5 CX38-49C 10551936
ML14XC1-047-230 TXV 46500 15.1 12.5 C35-48B EL180UH090E48B 9146178
ML14XC1-047-230 TXV 46500 15.1 12.5 C35-48B EL180UH090XE48B 9146179
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL180UH090E60C 9146180
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL180UH110E60C 9146181
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL180UH110XE60C 9146182
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL195UH090XE48C 9146183
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL195UH110XE60C 9146184
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL296UH090XE48C 9146185
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL296UH090XV48C 9146186
ML14XC1-047-230 TXV 47500 15.5 12.5 C35-49C EL296UH090XV60C 9146187
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C EL296UH110XE60C 9146188
ML14XC1-047-230 TXV 47500 15.1 12.5 C35-49C EL296UH110XV60C 9146189
ML14XC1-047-230 TXV 47500 15.5 12.5 C35-49C SL280UH090V60C 9146190
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C SL280UH110V60C 9146191
ML14XC1-047-230 TXV 47000 15.5 12.5 C35-49C SLP98UH090XV48C 9146192
ML14XC1-047-230 TXV 47500 15.5 12.5 C35-49C SLP98UH090XV60C 9146193
ML14XC1-047-230 TXV 47500 15.1 12.5 C35-49C SLP98UH110XV60C 9146194
ML14XC1-047-230 TXV 47000 14.5 12.2 C35-49C 9850163
ML14XC1-047-230 TXV 47000 14.5 12.2 C35-49C 9850173
ML14XC1-047-230 TXV 46000 15.1 12.5 C35-50/60C EL180UH090E60C 9146195
ML14XC1-047-230 TXV 46000 15.1 12.5 C35-50/60C EL180UH110E60C 9146196
ML14XC1-047-230 TXV 46000 15.1 12.5 C35-50/60C EL180UH110XE60C 9146197
ML14XC1-047-230 TXV 46000 15.1 12.5 C35-50/60C EL195UH090XE48C 9146198
ML14XC1-047-230 TXV 46000 15.1 12.5 C35-50/60C EL195UH110XE60C 9146199
ML14XC1-047-230 TXV 46000 15.1 12.5 C35-50/60C EL296UH090XE48C 9146200
ML14XC1-047-230 TXV 46000 15.1 12.5 C35-50/60C EL296UH110XE60C 9146201
ML14XC1-047-230 TXV 46000 14.5 12.2 C35-50/60C 9850164
ML14XC1-047-230 TXV 48000 16 13 C35-60C EL180UH090E60C 9146202
ML14XC1-047-230 TXV 48000 16 13 C35-60C EL180UH110E60C 9146203
ML14XC1-047-230 TXV 48000 16 13 C35-60C EL180UH110XE60C 9146204
ML14XC1-047-230 TXV 48000 15.5 12.5 C35-60C EL195UH090XE48C 9146205
ML14XC1-047-230 TXV 48000 16 13 C35-60C EL195UH110XE60C 9146206
ML14XC1-047-230 TXV 48000 15.5 12.5 C35-60C EL296UH090XE48C 9146207
ML14XC1-047-230 TXV 48000 16 13 C35-60C EL296UH110XE60C 9146208
ML14XC1-047-230 TXV 48000 16 13 C35-60C SL280UH090V60C 9146209
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MERIT ML14XC1 and is the answer not in the manual?

Lennox MERIT ML14XC1 Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
Cooling Capacity (BTU/h)18, 000 - 60, 000
Operating Voltage (VAC)208/230
Unit Weight (lbs)Varies by model
Dimensions (H x W x D, inches)Varies by model
Cooling Capacity1.5 to 5 tons
Warranty5-Year Limited Warranty on covered components

Related product manuals