AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-047-230 TXV 48000 16 13 C35-60C SL280UH090XV60C 9146210
ML14XC1-047-230 TXV 48000 16 13 C35-60C SL280UH110V60C 9146211
ML14XC1-047-230 TXV 48000 16 13 C35-60C SL280UH110XV60C 9146212
ML14XC1-047-230 TXV 48000 15.1 12.5 C35-60C 9146213
ML14XC1-047-230 TXV 48000 16 13 C35-60D EL180UH135E60D 9146214
ML14XC1-047-230 TXV 47500 15.5 12.5 C35-60D EL195UH135XE60D 9146215
ML14XC1-047-230 TXV 47500 15.5 12.5 C35-60D EL296UH135XE60D 9146216
ML14XC1-047-230 TXV 47000 14.5 12.2 C35-60D 9850165
ML14XC1-047-230 TXV 47000 16 13 CBA27UHE-048 10259428
ML14XC1-047-230 TXV 47000 15.1 12.5 CBX25UH-048 9146217
ML14XC1-047-230 TXV 47500 16 13 CBX25UHV-048 9146218
ML14XC1-047-230 TXV 47000 16 13 CBX27UH-048 9146219
ML14XC1-047-230 TXV 46500 16 13 CBX32MV-060 9146220
ML14XC1-047-230 TXV 47000 15.1 12.5 CBX40UHV-060 9146221
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-43 SL280UH090V60C 9146233
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-43 SL280UH110V60C 9146234
ML14XC1-047-230 TXV 47500 15.5 12.5 CH33-43B EL180UH090E48B 9146222
ML14XC1-047-230 TXV 47500 15.5 12.5 CH33-43B EL180UH090XE48B 9146223
ML14XC1-047-230 TXV 47500 15.1 12.5 CH33-43B SL280UH090V48B 9146224
ML14XC1-047-230 TXV 47500 15.1 12.5 CH33-43B SL280UH090XV48B 9146225
ML14XC1-047-230 TXV 46500 15.5 12.5 CH33-43C EL180UH090E60C 9146226
ML14XC1-047-230 TXV 46500 15.5 12.5 CH33-43C EL180UH110E60C 9146227
ML14XC1-047-230 TXV 46500 15.5 12.5 CH33-43C EL180UH110XE60C 9146228
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-43C EL195UH090XE48C 9146229
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-43C EL195UH110XE60C 9146230
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-43C EL296UH090XE48C 9146231
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-43C EL296UH110XE60C 9146232
ML14XC1-047-230 TXV 46500 14.5 12.2 CH33-43C 9146235
ML14XC1-047-230 TXV 46000 14.5 12.5 CH33-44/48 EL180UH090E48B 9146236
ML14XC1-047-230 TXV 46000 14.5 12.5 CH33-44/48 EL180UH090XE48B 9146237
ML14XC1-047-230 TXV 46000 14.5 12.2 CH33-44/48 SL280UH090V48B 9146238
ML14XC1-047-230 TXV 46000 14.5 12.2 CH33-44/48 SL280UH090XV48B 9146239
ML14XC1-047-230 TXV 46000 15.1 12.5 CH33-48C EL180UH090E60C 9146240
ML14XC1-047-230 TXV 46000 15.1 12.5 CH33-48C EL180UH110E60C 9146241
ML14XC1-047-230 TXV 46000 15.1 12.5 CH33-48C EL180UH110XE60C 9146242
ML14XC1-047-230 TXV 46000 15.1 12.5 CH33-48C EL195UH090XE48C 9146243
ML14XC1-047-230 TXV 46000 15.1 12.5 CH33-48C EL195UH110XE60C 9146244
ML14XC1-047-230 TXV 46000 15.1 12.5 CH33-48C EL296UH090XE48C 9146245
ML14XC1-047-230 TXV 46000 14.5 12.5 CH33-48C EL296UH090XV48C 9146246
ML14XC1-047-230 TXV 46500 14.5 12.5 CH33-48C EL296UH090XV60C 9146247
ML14XC1-047-230 TXV 46000 15.1 12.5 CH33-48C EL296UH110XE60C 9146248
ML14XC1-047-230 TXV 46500 14.5 12.5 CH33-48C EL296UH110XV60C 9146249
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-48C SL280UH090V60C 9146250
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-48C SL280UH090XV60C 9146251
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-48C SL280UH110V60C 9146252
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-48C SL280UH110XV60C 9146253
ML14XC1-047-230 TXV 46000 14.5 12.5 CH33-48C SLP98UH090XV48C 9146254
ML14XC1-047-230 TXV 46500 14.5 12.5 CH33-48C SLP98UH090XV60C 9146255
ML14XC1-047-230 TXV 46500 14.5 12.5 CH33-48C SLP98UH110XV60C 9146256
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MERIT ML14XC1 and is the answer not in the manual?

Lennox MERIT ML14XC1 Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
Cooling Capacity (BTU/h)18, 000 - 60, 000
Operating Voltage (VAC)208/230
Unit Weight (lbs)Varies by model
Dimensions (H x W x D, inches)Varies by model
Cooling Capacity1.5 to 5 tons
Warranty5-Year Limited Warranty on covered components