AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-047-230 TXV 46000 14.5 12.2 CH33-48C 9146257
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-49 EL180UH090E60C 9146258
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-49 EL180UH110E60C 9146259
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-49 EL180UH110XE60C 9146260
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-49 EL195UH090XE48C 9146261
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-49 EL195UH110XE60C 9146262
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-49 EL296UH090XE48C 9146263
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-49 EL296UH090XV48C 9146264
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-49 EL296UH090XV60C 9146265
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-49 EL296UH110XE60C 9146266
ML14XC1-047-230 TXV 47500 15.1 12.5 CH33-49 EL296UH110XV60C 9146267
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-49 SLP98UH090XV48C 9146268
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-49 SLP98UH090XV60C 9146269
ML14XC1-047-230 TXV 47500 15.1 12.5 CH33-49 SLP98UH110XV60C 9146270
ML14XC1-047-230 TXV 47000 14.5 12.2 CH33-49 9829640
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-50/60C EL180UH090E60C 9146271
ML14XC1-047-230 TXV 46500 15.5 12.5 CH33-50/60C EL180UH110E60C 9146272
ML14XC1-047-230 TXV 46500 15.5 12.5 CH33-50/60C EL180UH110XE60C 9146273
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-50/60C EL195UH090XE48C 9146274
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-50/60C EL195UH110XE60C 9146275
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-50/60C EL296UH090XE48C 9146276
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-50/60C EL296UH110XE60C 9146277
ML14XC1-047-230 TXV 47000 14.5 12.2 CH33-50/60C 9146278
ML14XC1-047-230 TXV 47000 15.5 12.5 CH33-60D EL180UH135E60D 9146279
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-60D EL195UH135XE60D 9146280
ML14XC1-047-230 TXV 46500 15.1 12.5 CH33-60D EL296UH135XE60D 9146281
ML14XC1-047-230 TXV 47500 15.5 12.5 CH33-62D EL180UH135E60D 9146282
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-62D EL195UH135XE60D 9146283
ML14XC1-047-230 TXV 47000 15.1 12.5 CH33-62D EL296UH135XE60D 9146284
ML14XC1-047-230 TXV 47500 15.5 12.5 CH35-42B EL180UH090E48B 9146285
ML14XC1-047-230 TXV 47500 15.1 12.5 CH35-42B SL280UH090XV48B 9146286
ML14XC1-047-230 TXV 47500 14.5 12.5 CH35-42B 9146287
ML14XC1-047-230 TXV 47000 15.5 12.5 CH35-42C EL180UH090E60C 9146288
ML14XC1-047-230 TXV 46500 15.5 12.5 CH35-42C EL180UH110E60C 9146289
ML14XC1-047-230 TXV 46500 15.1 12.5 CH35-42C EL195UH090XE48C 9146290
ML14XC1-047-230 TXV 47000 15.5 12.5 CH35-42C EL195UH110XE60C 9146291
ML14XC1-047-230 TXV 46500 15.1 12.5 CH35-42C EL296UH090XE48C 9146292
ML14XC1-047-230 TXV 47000 15.5 12.5 CH35-42C EL296UH110XE60C 9146293
ML14XC1-047-230 TXV 47000 15.5 12.5 CH35-42C SL280UH090V60C 9146294
ML14XC1-047-230 TXV 47000 15.1 12.5 CH35-42C SL280UH110V60C 9146295
ML14XC1-047-230 TXV 46500 15.1 12.5 CH35-42C SLP98UH090XV48C 9146296
ML14XC1-047-230 TXV 47000 15.1 12.5 CH35-42C SLP98UH090XV60C 9146297
ML14XC1-047-230 TXV 47000 15.1 12.5 CH35-42C SLP98UH110XV60C 9146298
ML14XC1-047-230 TXV 46500 14.5 12.2 CH35-42C 9146299
ML14XC1-047-230 TXV 46500 15.1 12.5 CH35-48B EL180UH090E48B 9146300
ML14XC1-047-230 TXV 46500 14.5 12.2 CH35-48B SL280UH090V48B 9146301
ML14XC1-047-230 TXV 46500 14.5 12.2 CH35-48B 9146302
ML14XC1-047-230 TXV 46500 15.5 12.5 CH35-48C EL180UH090E60C 9146303
ML14XC1-047-230 TXV 46500 15.5 12.5 CH35-48C EL180UH110E60C 9146304
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MERIT ML14XC1 and is the answer not in the manual?

Lennox MERIT ML14XC1 Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
Cooling Capacity (BTU/h)18, 000 - 60, 000
Operating Voltage (VAC)208/230
Unit Weight (lbs)Varies by model
Dimensions (H x W x D, inches)Varies by model
Cooling Capacity1.5 to 5 tons
Warranty5-Year Limited Warranty on covered components