AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S018, S024, S030, S036, S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1S042-230 TXV 40500 14.5 12.5 CH33-44/48B SLP98UH070XV36B 9150357
ML14XC1S042-230 TXV 41000 16 13 CH33-48C EL180UH090E60C 9147087
ML14XC1S042-230 TXV 41000 16 13 CH33-48C EL180UH110E60C 9147088
ML14XC1S042-230 TXV 41000 16 13 CH33-48C EL180UH110XE60C 9147089
ML14XC1S042-230 TXV 41000 15.5 13 CH33-48C EL195UH090XE48C 9147090
ML14XC1S042-230 TXV 41500 15.5 12.5 CH33-48C EL195UH110XE60C 9147091
ML14XC1S042-230 TXV 41000 15.5 13 CH33-48C EL296UH090XE48C 9147092
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C EL296UH090XV36C 9147093
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C EL296UH090XV48C 9147094
ML14XC1S042-230 TXV 41500 15.5 12.5 CH33-48C EL296UH090XV60C 9147095
ML14XC1S042-230 TXV 41500 15.5 12.5 CH33-48C EL296UH110XE60C 9147096
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C EL296UH110XV48C 9147097
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C EL296UH110XV60C 9147098
ML14XC1S042-230 TXV 41500 15.5 13 CH33-48C SL280UH090V60C 9147099
ML14XC1S042-230 TXV 41500 15.5 13 CH33-48C SL280UH090XV60C 9147100
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C SL280UH110V60C 9147101
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C SL280UH110XV60C 9147102
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C SLP98UH090XV36C 9147103
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C SLP98UH090XV48C 9147104
ML14XC1S042-230 TXV 41500 15.5 12.5 CH33-48C SLP98UH090XV60C 9147105
ML14XC1S042-230 TXV 41000 15.5 12.5 CH33-48C SLP98UH110XV60C 9147106
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL180UH090E60C 9147107
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL180UH110E60C 9147108
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL180UH110XE60C 9147109
ML14XC1S042-230 TXV 41500 16 13 CH33-49 EL195UH090XE48C 9147110
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL195UH110XE60C 9147111
ML14XC1S042-230 TXV 41500 16 13 CH33-49 EL296UH090XE48C 9147112
ML14XC1S042-230 TXV 41500 15.5 13 CH33-49 EL296UH090XV36C 9147113
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL296UH090XV48C 9147114
ML14XC1S042-230 TXV 42000 15.5 13 CH33-49 EL296UH090XV60C 9147115
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL296UH110XE60C 9147116
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL296UH110XV48C 9147117
ML14XC1S042-230 TXV 42000 16 13 CH33-49 EL296UH110XV60C 9147118
ML14XC1S042-230 TXV 42000 16 13 CH33-49 SL280UH090V60C 9147119
ML14XC1S042-230 TXV 42000 16 13 CH33-49 SL280UH090XV60C 9147120
ML14XC1S042-230 TXV 42000 16 13 CH33-49 SL280UH110V60C 9147121
ML14XC1S042-230 TXV 42000 16 13 CH33-49 SL280UH110XV60C 9147122
ML14XC1S042-230 TXV 41500 15.5 13 CH33-49 SLP98UH090XV36C 9147123
ML14XC1S042-230 TXV 42000 16 13 CH33-49 SLP98UH090XV48C 9147124
ML14XC1S042-230 TXV 42000 15.5 13 CH33-49 SLP98UH090XV60C 9147125
ML14XC1S042-230 TXV 42000 16 13 CH33-49 SLP98UH110XV60C 9147126
ML14XC1S042-230 TXV 41500 14.5 12.5 CH33-49 9147128
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL180UH090E60C 9147129
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL180UH110E60C 9147130
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL180UH110XE60C 9147131
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL195UH090XE48C 9147132
ML14XC1S042-230 TXV 42000 16 13 CH33-50/60C EL195UH110XE60C 9147133
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL296UH090XE48C 9147134
ML14XC1S042-230 TXV 41500 15.5 12.5 CH33-50/60C EL296UH090XV36C 9147135
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Related product manuals