EasyManua.ls Logo

Lennox MERIT ML14XC1 - Page 72

Lennox MERIT ML14XC1
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 72
AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S018, S024, S030, S036, S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL296UH090XV48C 9147136
ML14XC1S042-230 TXV 42000 15.5 12.5 CH33-50/60C EL296UH090XV60C 9147137
ML14XC1S042-230 TXV 42000 16 13 CH33-50/60C EL296UH110XE60C 9147138
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL296UH110XV48C 9147139
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C EL296UH110XV60C 9147140
ML14XC1S042-230 TXV 42000 16 13 CH33-50/60C SL280UH090V60C 9147141
ML14XC1S042-230 TXV 42000 16 13 CH33-50/60C SL280UH090XV60C 9147142
ML14XC1S042-230 TXV 41500 15.5 13 CH33-50/60C SL280UH110V60C 9147143
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C SL280UH110XV60C 9147144
ML14XC1S042-230 TXV 41500 15.5 12.5 CH33-50/60C SLP98UH090XV36C 9147145
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C SLP98UH090XV48C 9147146
ML14XC1S042-230 TXV 42000 15.5 12.5 CH33-50/60C SLP98UH090XV60C 9147147
ML14XC1S042-230 TXV 41500 16 13 CH33-50/60C SLP98UH110XV60C 9147148
ML14XC1S042-230 TXV 41000 14.5 12.2 CH33-50/60C 9147150
ML14XC1S042-230 TXV 42000 16 13 CH35-42B EL180UH090E48B 9147151
ML14XC1S042-230 TXV 42000 16 13 CH35-42B EL180UH090XE48B 9147152
ML14XC1S042-230 TXV 41500 15.5 12.5 CH35-42B EL296UH045XV36B 9147153
ML14XC1S042-230 TXV 41500 15.1 12.5 CH35-42B EL296UH070XV36B 9147154
ML14XC1S042-230 TXV 42000 16 13 CH35-42B SL280UH090V36B 9147155
ML14XC1S042-230 TXV 42000 16 13 CH35-42B SL280UH090V48B 9147156
ML14XC1S042-230 TXV 42000 16 13 CH35-42B SL280UH090XV48B 9147157
ML14XC1S042-230 TXV 41500 15.1 12.5 CH35-42B SLP98UH070XV36B 9147158
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL180UH090E60C 9147159
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL180UH110E60C 9147160
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL180UH110XE60C 9147161
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL195UH090XE48C 9147162
ML14XC1S042-230 TXV 42000 16 13 CH35-42C EL195UH110XE60C 9147163
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL296UH090XE48C 9147164
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL296UH090XV36C 9147165
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL296UH090XV48C 9147166
ML14XC1S042-230 TXV 42000 16 13 CH35-42C EL296UH090XV60C 9147167
ML14XC1S042-230 TXV 42000 16 13 CH35-42C EL296UH110XE60C 9147168
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL296UH110XV48C 9147169
ML14XC1S042-230 TXV 41500 16 13 CH35-42C EL296UH110XV60C 9147170
ML14XC1S042-230 TXV 42000 16 13 CH35-42C SL280UH090V60C 9147171
ML14XC1S042-230 TXV 42000 16 13 CH35-42C SL280UH090XV60C 9147172
ML14XC1S042-230 TXV 41500 16 13 CH35-42C SL280UH110V60C 9147173
ML14XC1S042-230 TXV 41500 16 13 CH35-42C SL280UH110XV60C 9147174
ML14XC1S042-230 TXV 41500 16 13 CH35-42C SLP98UH090XV36C 9147175
ML14XC1S042-230 TXV 41500 16 13 CH35-42C SLP98UH090XV48C 9147176
ML14XC1S042-230 TXV 42000 16 13 CH35-42C SLP98UH090XV60C 9147177
ML14XC1S042-230 TXV 41500 16 13 CH35-42C SLP98UH110XV60C 9147178
ML14XC1S042-230 TXV 41000 14.5 12.2 CH35-42C 9147179
ML14XC1S042-230 TXV 41500 15.5 13 CH35-48B EL180UH090E48B 9147180
ML14XC1S042-230 TXV 41500 15.5 13 CH35-48B EL180UH090XE48B 9147181
ML14XC1S042-230 TXV 41000 15.1 12.5 CH35-48B EL296UH045XV36B 9147182
ML14XC1S042-230 TXV 41000 15.1 12.5 CH35-48B EL296UH070XV36B 9147183
ML14XC1S042-230 TXV 41500 15.5 12.5 CH35-48B SL280UH090V36B 9147184
ML14XC1S042-230 TXV 41500 15.5 12.5 CH35-48B SL280UH090V48B 9147185
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.