AHRI SYSTEM MATCHES - SOUTHWEST REGIONS -018, -024, -030, 036, -042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-018-230 TXV 19800 16 13 CH33-25B EL195UH045XE24B 9141361
ML14XC1-018-230 TXV 19400 16 13 CH33-25B EL195UH045XE36B 9141362
ML14XC1-018-230 TXV 19400 16 13 CH33-25B EL296UH045XE36B 9141363
ML14XC1-018-230 TXV 19400 16 13 CH33-25B EL296UH045XV36B 9141364
ML14XC1-018-230 TXV 18000 16 13 CH33-31A EL180UH045E36A 9141365
ML14XC1-018-230 TXV 18000 16 13 CH33-31A EL180UH045XE36A 9141366
ML14XC1-018-230 TXV 18000 14.5 12.2 CH33-31A 9141368
ML14XC1-018-230 TXV 18000 16 13 CH33-31B EL180UH070E36B 9141369
ML14XC1-018-230 TXV 18000 16 13 CH33-31B EL180UH070XE36B 9141370
ML14XC1-018-230 TXV 20000 16 13.5 CH33-31B EL195UH030XE24B 9141371
ML14XC1-018-230 TXV 20000 16 13.5 CH33-31B EL195UH045XE24B 9141372
ML14XC1-018-230 TXV 18000 16 13 CH33-31B EL195UH045XE36B 9141373
ML14XC1-018-230 TXV 18000 16 13 CH33-31B EL296UH045XE36B 9141374
ML14XC1-018-230 TXV 20000 17 13.5 CH33-31B EL296UH045XV36B 9141375
ML14XC1-018-230 TXV 18000 14.5 12.2 CH33-31B 9141377
ML14XC1-018-230 TXV 18000 16 13 CH35-18A EL180UH045E36A 9141378
ML14XC1-018-230 TXV 18000 16 13 CH35-18A EL180UH045XE36A 9141379
ML14XC1-018-230 TXV 18000 16 13 CH35-24A EL180UH045E36A 9141380
ML14XC1-018-230 TXV 18000 16 13 CH35-24A EL180UH045XE36A 9141381
ML14XC1-018-230 TXV 18000 15.5 12.5 CH35-24B EL180UH070E36B 9141382
ML14XC1-018-230 TXV 18000 15.5 12.5 CH35-24B EL180UH070XE36B 9141383
ML14XC1-018-230 TXV 19800 16 13 CH35-24B EL195UH030XE24B 9141384
ML14XC1-018-230 TXV 19800 16 13 CH35-24B EL195UH045XE24B 9141385
ML14XC1-018-230 TXV 18000 15.5 12.5 CH35-24B EL195UH045XE36B 9141386
ML14XC1-018-230 TXV 18000 15.5 12.5 CH35-24B EL296UH045XE36B 9141387
ML14XC1-018-230 TXV 19600 16 13 CH35-24B EL296UH045XV36B 9141388
ML14XC1-018-230 TXV 18000 16 13 CH35-30A EL180UH045E36A 9141389
ML14XC1-018-230 TXV 18000 16 13 CH35-30A EL180UH045XE36A 9141390
ML14XC1-018-230 TXV 18000 14.5 12.2 CH35-30A 9141391
ML14XC1-018-230 TXV 18000 16 13 CH35-30B EL180UH070E36B 9141392
ML14XC1-018-230 TXV 18000 16 13 CH35-30B EL180UH070XE36B 9141393
ML14XC1-018-230 TXV 20000 16 13.5 CH35-30B EL195UH030XE24B 9141394
ML14XC1-018-230 TXV 20000 16 13.5 CH35-30B EL195UH045XE24B 9141395
ML14XC1-018-230 TXV 18000 16 13 CH35-30B EL195UH045XE36B 9141396
ML14XC1-018-230 TXV 18000 16 13 CH35-30B EL296UH045XE36B 9141397
ML14XC1-018-230 TXV 19600 17 13.5 CH35-30B EL296UH045XV36B 9141398
ML14XC1-018-230 TXV 18000 14.5 12.2 CH35-30B 9141399
ML14XC1-018-230 TXV 18000 15.5 12.5 CR33-18 EL180DF045E36A 9141400
ML14XC1-018-230 TXV 18000 15.1 12.5 CR33-24A EL180DF045E36A 9141401
ML14XC1-018-230 TXV 18000 14.5 12.5 CR33-24B EL180DF070E36B 9141402
ML14XC1-018-230 TXV 18000 14.5 12.2 CR33-24B EL195DF045E36B 9141403
ML14XC1-018-230 TXV 18000 14.5 12.2 CR33-24B EL195DF070XE48B 10498871
ML14XC1-018-230 TXV 18000 16 13 CR33-30/36A EL180DF045E36A 9141405
ML14XC1-018-230 TXV 18000 14.5 12.2 CR33-30/36A 9141407
ML14XC1-018-230 TXV 18000 15.5 13 CR33-30/36B EL180DF070E36B 9141408
ML14XC1-018-230 TXV 18000 15.5 12.5 CR33-30/36B EL195DF045E36B 9141409
ML14XC1-018-230 TXV 18000 15.5 12.5 CR33-30/36B EL195DF070XE48B 10498872
ML14XC1-018-230 TXV 18000 14.5 12.2 CR33-30/36B 9141412
ML14XC1-018-230 TXV 18800 15.5 12.5 CX35-18/24A EL180UH045E36A 9144622
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MERIT ML14XC1 and is the answer not in the manual?

Lennox MERIT ML14XC1 Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
Cooling Capacity (BTU/h)18, 000 - 60, 000
Operating Voltage (VAC)208/230
Unit Weight (lbs)Varies by model
Dimensions (H x W x D, inches)Varies by model
Cooling Capacity1.5 to 5 tons
Warranty5-Year Limited Warranty on covered components