ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 80
AHRI SYSTEM MATCHES - SOUTHWEST REGIONS -018, -024, -030, 036, -042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-018-230 TXV 18800 15.5 12.5 CX35-18/24A EL180UH045XE36A 9144623
ML14XC1-018-230 TXV 18800 15.5 12.5 CX35-18/24B EL180UH070E36B 9141457
ML14XC1-018-230 TXV 18800 15.5 12.5 CX35-18/24B EL180UH070XE36B 9141458
ML14XC1-018-230 TXV 18800 15.5 12.5 CX35-18/24B EL195UH045XE36B 9141459
ML14XC1-018-230 TXV 18800 15.5 12.5 CX35-18/24B EL296UH045XE36B 9141460
ML14XC1-018-230 TXV 18000 16 13 CX35-24A EL180UH045E36A 9141461
ML14XC1-018-230 TXV 18000 16 13 CX35-24A EL180UH045XE36A 9141462
ML14XC1-018-230 TXV 18000 15.5 12.5 CX35-24B EL180UH070E36B 9141463
ML14XC1-018-230 TXV 18000 15.5 12.5 CX35-24B EL180UH070XE36B 9141464
ML14XC1-018-230 TXV 19800 16 13 CX35-24B EL195UH030XE24B 9141465
ML14XC1-018-230 TXV 19800 16 13 CX35-24B EL195UH045XE24B 9141466
ML14XC1-018-230 TXV 19600 16 13 CX35-24B EL195UH045XE36B 9141467
ML14XC1-018-230 TXV 19600 16 13 CX35-24B EL296UH045XE36B 9141468
ML14XC1-018-230 TXV 19600 16 13 CX35-24B EL296UH045XV36B 9141469
ML14XC1-018-230 TXV 19800 16 13 CX35-24B EL296UH070XV36B 9141470
ML14XC1-018-230 TXV 19800 16 13 CX35-24B SLP98UH070XV36B 9141471
ML14XC1-018-230 TXV 18000 16 13 CX35-30A EL180UH045E36A 9141472
ML14XC1-018-230 TXV 18000 16 13 CX35-30A EL180UH045XE36A 9141473
ML14XC1-018-230 TXV 18000 14.5 12.2 CX35-30A 9141474
ML14XC1-018-230 TXV 18000 15.5 13 CX35-30B EL180UH070E36B 9141475
ML14XC1-018-230 TXV 18000 15.5 13 CX35-30B EL180UH070XE36B 9141476
ML14XC1-018-230 TXV 20000 16 13.5 CX35-30B EL195UH030XE24B 9141477
ML14XC1-018-230 TXV 20000 16 13.5 CX35-30B EL195UH045XE24B 9141478
ML14XC1-018-230 TXV 18000 16 13 CX35-30B EL195UH045XE36B 9141479
ML14XC1-018-230 TXV 18000 16 13 CX35-30B EL296UH045XE36B 9141480
ML14XC1-018-230 TXV 20000 16 13.5 CX35-30B EL296UH045XV36B 9141481
ML14XC1-018-230 TXV 20000 17 13.5 CX35-30B EL296UH070XV36B 9141482
ML14XC1-018-230 TXV 20000 17 13.5 CX35-30B SLP98UH070XV36B 9141483
ML14XC1-018-230 TXV 18000 14.5 12.2 CX35-30B 9141484
ML14XC1-018-230 TXV 18000 14.25 12.2 CX38-25B 10550975
ML14XC1-024-230 RFC 24000 14.25 12.2 CH33-31A 9141762
ML14XC1-024-230 RFC 24000 14.25 12.2 CH33-31B 9141776
ML14XC1-024-230 RFC 24000 14 12.2 CH33-42B 9141798
ML14XC1-024-230 RFC 24000 14.25 12.2 CH33-43B 9141802
ML14XC1-024-230 TXV 24000 16 13 C35-24A EL180UH045E36A 9141613
ML14XC1-024-230 TXV 24000 16 13 C35-24A EL180UH045XE36A 9141614
ML14XC1-024-230 TXV 24000 16 13 C35-24A SL280UH070V36A 9141615
ML14XC1-024-230 TXV 24000 16 13 C35-24A SL280UH070XV36A 9141616
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL180UH070E36B 9141617
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL180UH070XE36B 9141618
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL195UH030XE24B 9141619
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL195UH045XE24B 9141620
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL195UH045XE36B 9141621
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL195UH070XE36B 9141622
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL296UH045XE36B 9141623
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL296UH045XV36B 9141624
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL296UH070XE36B 9141625
ML14XC1-024-230 TXV 24000 16 13 C35-24B EL296UH070XV36B 9141626
ML14XC1-024-230 TXV 24000 16 13 C35-24B SL280UH090V36B 9141627
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.