ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 93
AHRI SYSTEM MATCHES - SOUTHWEST REGIONS -018, -024, -030, 036, -042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-030-230 TXV 30000 16 13 CH35-42B EL180UH070E36B 9142437
ML14XC1-030-230 TXV 30000 16 13 CH35-42B EL180UH070XE36B 9142438
ML14XC1-030-230 TXV 30000 16 13 CH35-42B EL180UH090E48B 9142439
ML14XC1-030-230 TXV 30000 16 13 CH35-42B EL180UH090XE48B 9142440
ML14XC1-030-230 TXV 29800 16 13 CH35-42B EL195UH045XE36B 9142441
ML14XC1-030-230 TXV 30000 16 13 CH35-42B EL195UH070XE36B 9142442
ML14XC1-030-230 TXV 29800 16 13 CH35-42B EL296UH045XE36B 9142443
ML14XC1-030-230 TXV 29800 16 13 CH35-42B EL296UH045XV36B 9142444
ML14XC1-030-230 TXV 30000 16 13 CH35-42B EL296UH070XE36B 9142445
ML14XC1-030-230 TXV 29800 16 13 CH35-42B EL296UH070XV36B 9142446
ML14XC1-030-230 TXV 29800 16 13 CH35-42B SL280UH090V36B 9142447
ML14XC1-030-230 TXV 29800 16 13 CH35-42B SLP98UH070XV36B 9142448
ML14XC1-030-230 TXV 29400 14.5 12.5 CH35-42B 9142449
ML14XC1-030-230 TXV 29600 16 13 CH35-42C EL195UH090XE48C 9142450
ML14XC1-030-230 TXV 29600 16 13 CH35-42C EL296UH090XE48C 9142451
ML14XC1-030-230 TXV 29400 16 13 CH35-42C EL296UH090XV36C 9142452
ML14XC1-030-230 TXV 29400 16 13 CH35-42C SLP98UH090XV36C 9142453
ML14XC1-030-230 TXV 29000 14.5 12.2 CH35-42C 9142454
ML14XC1-030-230 TXV 27000 14.5 12.2 CR33-24A EL180DF045E36A 9142455
ML14XC1-030-230 TXV 26800 14.5 12.2 CR33-24B EL180DF070E36B 9142456
ML14XC1-030-230 TXV 27000 14.25 12.2 CR33-24B EL296DF045XV36B 9142457
ML14XC1-030-230 TXV 26800 14.25 12.2 CR33-24B SL280DF090V48B 9142458
ML14XC1-030-230 TXV 28800 15.5 12.5 CR33-30/36A EL180DF045E36A 9142459
ML14XC1-030-230 TXV 28800 15.5 12.5 CR33-30/36A SL280DF070V36A 9142460
ML14XC1-030-230 TXV 28800 16 13 CR33-30/36B EL180DF070E36B 9142461
ML14XC1-030-230 TXV 28600 16 13 CR33-30/36B EL180DF090E48B 9142462
ML14XC1-030-230 TXV 28600 15.1 12.5 CR33-30/36B EL195DF045XE36B 9142463
ML14XC1-030-230 TXV 28800 15.5 12.5 CR33-30/36B EL195DF070XE48B 9142464
ML14XC1-030-230 TXV 28600 15.1 12.5 CR33-30/36B EL296DF045XE36B 9142465
ML14XC1-030-230 TXV 28800 15.5 12.5 CR33-30/36B EL296DF045XV36B 9142466
ML14XC1-030-230 TXV 28800 15.5 12.5 CR33-30/36B EL296DF070XE48B 9142467
ML14XC1-030-230 TXV 28600 15.5 12.5 CR33-30/36B EL296DF070XV48B 9142468
ML14XC1-030-230 TXV 28400 15.5 12.5 CR33-30/36B SL280DF090V48B 9142469
ML14XC1-030-230 TXV 28600 15.5 12.5 CR33-30/36B SLP98DF070XV36B 9142470
ML14XC1-030-230 TXV 28800 16 13 CR33-30/36C SLP98DF090XV36C 9142471
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-24A EL180UH045E36A 9142593
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-24A EL180UH045XE36A 9142594
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-24A SL280UH070V36A 9142595
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-24A SL280UH070XV36A 9142596
ML14XC1-030-230 TXV 28600 15.5 13 CX35-24B EL180UH070E36B 9142597
ML14XC1-030-230 TXV 28600 15.5 13 CX35-24B EL180UH070XE36B 9142598
ML14XC1-030-230 TXV 28600 15.5 13 CX35-24B EL180UH090E48B 9142599
ML14XC1-030-230 TXV 28600 15.5 13 CX35-24B EL180UH090XE48B 9142600
ML14XC1-030-230 TXV 28600 15.1 12.5 CX35-24B EL195UH045XE36B 9142601
ML14XC1-030-230 TXV 28800 15.1 12.5 CX35-24B EL195UH070XE36B 9142602
ML14XC1-030-230 TXV 28600 15.1 12.5 CX35-24B EL296UH045XE36B 9142603
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-24B EL296UH045XV36B 9142604
ML14XC1-030-230 TXV 28800 15.1 12.5 CX35-24B EL296UH070XE36B 9142605
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-24B EL296UH070XV36B 9142606
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.