AHRI SYSTEM MATCHES - SOUTHWEST REGIONS -018, -024, -030, 036, -042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-030-230 TXV 28600 16 13 CX35-24B SL280UH090V36B 9142607
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-24B SLP98UH070XV36B 9142608
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-30/36A EL180UH045E36A 9142609
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-30/36A EL180UH045XE36A 9142610
ML14XC1-030-230 TXV 28400 15.5 12.5 CX35-30/36A SL280UH070V36A 9142611
ML14XC1-030-230 TXV 28400 15.5 12.5 CX35-30/36A SL280UH070XV36A 9142612
ML14XC1-030-230 TXV 28600 15.5 13 CX35-30/36B EL180UH070E36B 9142613
ML14XC1-030-230 TXV 28600 15.5 13 CX35-30/36B EL180UH070XE36B 9142614
ML14XC1-030-230 TXV 28600 16 13 CX35-30/36B EL180UH090E48B 9142615
ML14XC1-030-230 TXV 28600 16 13 CX35-30/36B EL180UH090XE48B 9142616
ML14XC1-030-230 TXV 28600 15.1 12.5 CX35-30/36B EL195UH045XE36B 9142617
ML14XC1-030-230 TXV 28600 15.1 12.5 CX35-30/36B EL195UH070XE36B 9142618
ML14XC1-030-230 TXV 28600 15.1 12.5 CX35-30/36B EL296UH045XE36B 9142619
ML14XC1-030-230 TXV 28600 15.1 12.5 CX35-30/36B EL296UH045XV36B 9142620
ML14XC1-030-230 TXV 28600 15.1 12.5 CX35-30/36B EL296UH070XE36B 9142621
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-30/36B EL296UH070XV36B 9142622
ML14XC1-030-230 TXV 28600 15.5 13 CX35-30/36B SL280UH090V36B 9142623
ML14XC1-030-230 TXV 28600 15.5 12.5 CX35-30/36B SLP98UH070XV36B 9142624
ML14XC1-030-230 TXV 28400 15.5 12.5 CX35-30/36C EL195UH090XE48C 9142625
ML14XC1-030-230 TXV 28400 15.5 13 CX35-30/36C EL296UH090XE48C 9142627
ML14XC1-030-230 TXV 28400 15.5 12.5 CX35-30/36C EL296UH090XV36C 9142626
ML14XC1-030-230 TXV 28400 15.5 13 CX35-30/36C SLP98UH090XV36C 9142628
ML14XC1-030-230 TXV 29200 15.5 13 CX35-30A EL180UH045E36A 9142629
ML14XC1-030-230 TXV 29200 15.5 13 CX35-30A EL180UH045XE36A 9142630
ML14XC1-030-230 TXV 29200 16 13 CX35-30A SL280UH070V36A 9142631
ML14XC1-030-230 TXV 29200 16 13 CX35-30A SL280UH070XV36A 9142632
ML14XC1-030-230 TXV 28600 14.25 12.2 CX35-30A 9142633
ML14XC1-030-230 TXV 29200 16 13 CX35-30B EL180UH070E36B 9142634
ML14XC1-030-230 TXV 29200 16 13 CX35-30B EL180UH070XE36B 9142635
ML14XC1-030-230 TXV 29200 16 13 CX35-30B EL180UH090E48B 9142636
ML14XC1-030-230 TXV 29200 16 13 CX35-30B EL180UH090XE48B 9142637
ML14XC1-030-230 TXV 29200 15.5 12.5 CX35-30B EL195UH045XE36B 9142638
ML14XC1-030-230 TXV 29400 15.5 12.5 CX35-30B EL195UH070XE36B 9142639
ML14XC1-030-230 TXV 29200 15.5 12.5 CX35-30B EL296UH045XE36B 9142640
ML14XC1-030-230 TXV 29200 15.5 12.5 CX35-30B EL296UH045XV36B 9142641
ML14XC1-030-230 TXV 29400 15.5 12.5 CX35-30B EL296UH070XE36B 9142642
ML14XC1-030-230 TXV 29200 16 13 CX35-30B EL296UH070XV36B 9142643
ML14XC1-030-230 TXV 29200 16 13 CX35-30B SL280UH090V36B 9142644
ML14XC1-030-230 TXV 29200 16 13 CX35-30B SLP98UH070XV36B 9142645
ML14XC1-030-230 TXV 28600 14.25 12.2 CX35-30B 9142646
ML14XC1-030-230 TXV 29400 16 13 CX35-36A EL180UH045E36A 9142647
ML14XC1-030-230 TXV 29400 16 13 CX35-36A EL180UH045XE36A 9142648
ML14XC1-030-230 TXV 29400 16 13 CX35-36A SL280UH070V36A 9142649
ML14XC1-030-230 TXV 29400 16 13 CX35-36A SL280UH070XV36A 9142650
ML14XC1-030-230 TXV 28800 14.5 12.2 CX35-36A 9142651
ML14XC1-030-230 TXV 29600 16 13 CX35-36B EL180UH070E36B 9142652
ML14XC1-030-230 TXV 29600 16 13 CX35-36B EL180UH070XE36B 9142653
ML14XC1-030-230 TXV 29600 16 13 CX35-36B EL180UH090E48B 9142654
ML14XC1-030-230 TXV 29600 16 13 CX35-36B EL180UH090XE48B 9142655
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.