MP-36OD
P/N 775,540M REV. A 04/2006
Page 1 of 2
Appliance Specifi cations
Notes
Due to Lennox' ongoing commitment to quality,
all specifi cations, ratings and dimensions are
subject to change without notice.
All framing dimensions calculated for 1/2" dry wall
at the fi replace face. If sheathing the chase or
nishing with other thickness materials, calcula-
tions will need to be made.
See Installation Instuctions Manual for Ceiling
and Roof Framing Dimensions.
Diagrams & Illustrations Not to Scale
Product Reference Information
Cat.
No.
Model Ship.
Weight
Ship.
Volume
H1933 MP-36OD 175 lb. 17.3 cu. ft.
40"
(1016 mm)
Front
37"
(940 mm)
7-3/16”
(183 mm)
36"
(914 mm)
2"
(51 mm)
12-1/2"
(318 mm)
37"
(940 mm)
20-1/4”
(514 mm)
Left Side
Right Side
40"
(1016 mm)
27-1/4”
(692 mm)
20-1/4”
(514 mm)
7-13/16
(198 mm)
Top View
Gas Line
Access
Combustion
Air Inlet
20-3/16”
(513 mm)
9-7/8”
(251 mm)
17-3/8”
(441 mm)
32"
(813 mm)
9-5/8”
(244 mm)
7-1/2”
(191 mm)
27-7/8”
(708 mm)
Appliance Top Spacer
Appliance
Top Spacer
Junction
Box
Gas Line
Access
42-1/2"
(1080 mm)
42-1/2"
(1080 mm)
1-1/4"
(32 mm)
9-1/16
(230 mm)
12-7/8”
(327 mm)
9-3/16”
(233 mm)
Fireplace Framing
Header
(See Note **
)
B
1
A
B
2
A
K
G
Inside Chase
Back Wall of Chase/Enclosure
Including Finishing Materials, if any.
Rough
Framing Face
(Unfinished Shown)
OAK-OD Combustion
Air Kit
A
Outside Chase
G
C
H
I
nc
l
u
di
ng
Fi
n
i
s
i
ng
M
ater
i
a
l
s
if any
Rough
Framing Face
(Unfinished Shown)
Combustion
Air Kit - Optional
*
Outside Chase - Indoor Installations
Outside
Air Kit
G
A
Outside Chase
Back Wall of Chase/Enclosure
Including Finishing
Materials if any
Rough Framing Face
(Unfinished Shown)
Optional
Drainage
Line
**Note: When Framing With 6” Studs Header Must Be 17”
(432mm) Higher. Use Security Chimney’s OR15 Offset/Return
Elbow To Recess The Chimney Back 2 1/2” (64mm). Flat Frame
Down To A False Header At (B
1
). Maintain Required Clearance
To Chimney At All Times.
* 1" Air Space to insulation & construction materials on back and sides.
OTL Report No. 116-F-35-2
Corner Installation
J
D
A
E
F
Back Wall of
Chase/Enclosure
Including Finising
Materials
if any
Rough
Framing Face
(Unfinished Shown)
OAK-OD Combustion
Air Kit
Framing Dimensions
A 41-1/2" 1054 mm
B
1
37-1/2" 953 mm
B
2
54-1/2" 1384 mm
C 28-3/4" 730 mm
D 15-3/8" 391 mm
E 70" 1778 mm
F 35" 889 mm
G 20-5/8" 524 mm
H 19-5/8" 499 mm
J 49-1/2" 1257 mm
K 8" 203 mm

Questions and Answers

  • S
    Stephanie GreeneAug 10, 2025
    What to do if my Lennox MP-360D smokes after an hour or two?
    • U
      ucruzAug 10, 2025
      If your Lennox Indoor Fireplace smokes an hour or two after lighting, especially in a well-insulated house, the issue might be that your house is too airtight. To resolve this, check if your outside combustion air kit is open and free from obstructions outside. You can also try opening a window slightly or opening doors to one or two rooms to see if it stops the smoking.
  • T
    tony37Aug 15, 2025
    Why is my Lennox MP-360D smoking because of vent fan?
    • J
      James SmithAug 15, 2025
      If a vent fan, exhaust hood, or central heating/cooling system is stealing combustion air from your Lennox Indoor Fireplace, it can cause negative pressure and an unwanted downdraft, leading to smoking if their volume is high enough.
  • S
    Sherry WoodsAug 20, 2025
    How to stop smoke escaping into the room when lighting Lennox MP-360D Indoor Fireplace?
    • C
      Corey TaylorAug 20, 2025
      When lighting your Lennox Indoor Fireplace, a little smoke may escape into the room if the chimney is cold. To correct this, hold a lighted newspaper up inside the firebox near the open flue damper.
  • J
    Jared StephensonAug 25, 2025
    Why my Lennox MP-360D smoking because of the wind?
    • B
      Brett WileyAug 26, 2025
      A breeze or wind blowing can cause negative pressure and an unwanted downdraft, leading to smoking in your Lennox Indoor Fireplace.
  • M
    Matthew EsparzaAug 30, 2025
    What to do if fire is too far forward in Lennox MP-360D?
    • S
      schultzmackenzieAug 30, 2025
      If your fire is too far forward in your Lennox Indoor Fireplace, move it toward the back with your poker. Keep the fire well within the confines of your fuel grate.
  • S
    Samantha RichardsSep 4, 2025
    How to maintain air movement around logs in Lennox MP-360D?
    • J
      Jacqueline HullSep 4, 2025
      To ensure proper operation of your Lennox Indoor Fireplace, the fire needs plenty of air movement around the logs. Keep your fire up on the grate and the refractory below free of excessive ashes.

Lennox MP-360D Specifications

General IconGeneral
BrandLennox
ModelMP-360D
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals