10/09 505,276M
*2P1009* *P505276M*
Page 1
AIR CLEANERS / FILTERS
Litho U.S.A.
E2009 Lennox Industries Inc.
Dallas, Texas, USA
505,276M
10/09
Supersedes 07/09
PUREAIRt AIR PURIFICATION SYSTEM
PHOTOCATALYTIC OXIDATION (PCO)
TECHNOLOGY
INSTALLATION INSTRUCTIONS FOR PUREAIRT AIR PURIFICATION SYSTEM
MODELS PCO14−23, PCO16−28 AND PCO20−28
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Shipping & Packing List
Assembled PureAirt air purification system which in-
cludes:
1 − Cabinet
1 − Control box assembly (includes frame, ballasts
and associated wiring)
1 − MERV 16 pleated filter
2 − UVA lamps
1 − Titanium dioxide metal insert
1 − Power cord (120VAC)*
*230VAC power cord available separately (part number
91X44).
A warranty certificate and registration card are also in-
cluded.
Shipping Damage
Check equipment for shipping damage. If damage is
found, immediately contact last carrier.
General Information
The PureAirt air purification system uses photocatalytic
oxidation (PCO) technology to significantly reduce levels
of airborne volatile organic compounds, cooking odors,
common household odors, airborne dust particles, mold
spores and pollen. The PureAirt system is available in
three models: PCO14−23, PCO16−28 and PCO20−28.
Each unit may be connected to either 120VAC or 230VAC
power supply. If 230VAC power supply is used, a 230VAC
power cord must be ordered separately.
Lab tests confirm a 50% reduction in total volatile organic
compounds (TVOC) within the first 24 hours of initial op-
eration of the PureAirt air purification system. It may take
up to 48 hours after initial system start−up to reduce the air-
borne chemicals that have built up in a home over a long
period of time.
For peak performance, unit should be installed in homes
with TVOC levels that are less than 1000 µg/m
3
. Home
source removal and ventilation may be required to lower
TVOCs to this level.
NOTICE
This system is NOT intended to be used for removal
of active mold growth or continuous sources of
high levels of chemicals in the air.
For existing mold growth, the mold must be proper-
ly removed PRIOR to installation of the PureAirt air
purification system.
WARNING
Risk of property damage, injury, or death.
Installation and service must be performed by a
qualified installer or service agency.
WARNING
Electric shock hazard.
Can cause injury or death.
Disconnect all electrical power supplies before ser-
vicing. Access panels must be in place during ap-
pliance operation.
CAUTION
Sharp edges hazard.
Sharp edges can cause injuries.
Use protective gloves when grasping equipment
edges.
NOTICE
Possible odor emissions. Chemical reactions may
cause temporary odors after initial start−up or after
lamp replacement. Odor may also be present after
paint, cleaning solutions or hobby materials have
been used in the conditioned space.
Some occupants may experience irritation or dis-
comfort during this period. If the irritation or dis-
comfort lasts longer than 48 hours, the homeowner
should be advised to contact a Lennox dealer.
Unique Field−Supplied Installation Items
S Cotton gloves and cloth (to remove fingerprints from
lamps)
S Aluminum foil tape or water−based mastic (NOT sili-
cone) to be applied as a sealant.
Question and Answer IconNeed help?

Do you have a question about the Lennox PUREAIR PCO14-23 and is the answer not in the manual?

Lennox PUREAIR PCO14-23 Specifications

General IconGeneral
Product TypeAir Cleaner
Model NumberPCO14-23
Photocatalytic Oxidation (PCO)Yes
Voltage120V
Power Supply120V AC
Filter TypeHEPA
TechnologyPhotocatalytic Oxidation (PCO)

Summary

General Information

Shipping & Packing List

Lists all components included in the PureAir™ air purification system package.

Safety Warnings and Notices

Compiles critical safety warnings, cautions, and important notices for system installation and operation.

Parts Identification and Installation

Component Identification Diagram

Visual guide identifying all key components of the PureAir™ system.

Installation Examples

Demonstrates various recommended installation configurations for the PCO unit in ductwork.

Duct Transition Guidelines

Provides guidance on creating proper duct transitions for unit installation.

Dimensions and Specifications

Installation Location and Clearance

Details required service clearance and optimal placement for the PCO unit installation.

Lamp Orientation Notice

Important advisory on maintaining horizontal lamp orientation for effective operation.

Installation Preparation and Cabinet Mounting

Installation Notices and Requirements

Covers essential notices for installation, unpacking, sealant, and cord safety.

Mercury Lamp Handling Caution

Specific caution regarding the health hazards associated with handling mercury-containing lamps.

Installing PCO Cabinet

Step-by-step instructions for securely mounting the PCO unit cabinet to the air handler.

System Installation and Operation

Installing Filter and Metal Insert

Procedure for correctly installing the MERV 16 filter and titanium dioxide metal insert.

System Operation Guidelines

Recommendations for optimal system performance, including fan settings and humidity.

Safety Precautions During Operation

Warnings on UVA radiation, carbon monoxide risk, and securing access doors.

Maintenance and Component Replacement

Filter, Insert, and Lamp Replacement

Detailed procedure for replacing the MERV 16 filter, metal insert, and UVA lamps.

Maintenance Safety Precautions

Crucial safety warnings for electric shock, hot lamps, and mercury exposure during maintenance.

Broken Lamp Clean-up and Disposal

Guidelines for safely cleaning up and disposing of broken UVA lamps.

Troubleshooting and Parts Information

Troubleshooting Flow Chart Reference

Directs users to the troubleshooting flow chart for issue diagnosis.

Annual Maintenance Kits

Information on kits available for performing annual maintenance on the system.

Replacement Parts List

A comprehensive list of available replacement parts with their part numbers.

Troubleshooting Guide

Voltage Readings for Troubleshooting

Table of voltage readings for diagnosing system issues, including service actions.

Related product manuals