Page 49
(Unit shownin upflow position withremote trap)
*5’ max.
To Drain
PVCPipeOnly
FieldProvidedVent
Min.1” Above Condensate
Drain
Connection
1”
Min.
Trap CanBeInstalleda
Maximum 5’ From Furnac
e
2” Max.
CONDENSATE TRAP LOCATIONS
*Piping from furnace must slope down a
minimum 1/4” per ft. toward trap
FIGURE 37
HorizontalFurnace4” Min.to5” Max.above
condensatedrain connection)
FurnaceCondensate
Drain
Connection
From Evaporator Coil
Optional
Condensate Trap With Optional Overflow Switch
FIGURE 38
Coil Using A Separate Drain
Condensate
Drain
Connection
ield Provided Vent
” min. 2” max. above
connection)
Evaporator drain
line required
(Trap at coil is optional)
FIGURE 39
Furnace with Evaporator
Coil Using a Common Drain
(1” min.to2” Max.above
condensatedrain connection)
Condensate
Drain
Connection
Evaporator drain
line required
(Trap at coil is optional)
FIGURE 40