Page 12
Venting Options
The SLP98DF is shipped with vent exhaust / air intake 
connection at the top cap. See gure 13. Using parts pro-
vided,  the  furnace  may  be  eld  modied  to  have  these 
connections on the right side of the furnace cabinet. See 
gure 15 and follow the steps below. For left side venting 
order kit 87W73.
1 -  Remove inner blower door.
2 -   Loosen hose clamps which attach rubber ttings to 
the white PVC pipes inside the vestibule area. See 
gure 13.
3 -   Loosen the clamp which secures the pipes at the 
blower deck. See gure 13.
4 -   Remove white PVC pipes, slide up and out thru the 
top cap.
5 -   Remove the remaining parts of the pipe clamp at 
the blower deck.
6 -   Remove  the  black  plastic  tting  in  top  cap  which 
previously aligned the PVC pipes.
7 -   Remove the sheet metal patch plate on the side 
of the cabinet which covers the openings for side 
venting option. Save screws for reuse.
8 -   Re-use the patch plate to cover the hole in the top 
cap.  See  gure  14.  Remove  the  2  screws  which 
secure the top cap to the furnace on the right side 
and re-install securing the right edge of the patch 
plate and the right side of the top cap to the furnace. 
Use 2 self-drilling sheet metal screws (provided) to 
nish  securing  the  left  edge  of  the  patch  plate  on 
the left side.
9 -   Use a utility knife to cut out the cabinet insulation for 
the right side vent / air intake.
10 -  Install the two 90° street elbows (provided) through 
the side of the cabinet. The male side of each 
elbow should extend down through the blower deck 
and connect to the rubber ttings below. Once the 
elbows are properly positioned, tighten each clamp.
11 -  Peel protective backing from side vent sealing 
gaskets (2) and apply to side vent sealing plates (2) 
as shown in gure 15.
12 -  Install the side vent sealing plates and gaskets 
on  the  exterior  of  the  cabinet  as  shown  in  gure 
15. Secure with six mounting screws (four reused 
and two provided from bag assembly). Holes are 
pre-punched in the parts and cabinet, no drilling is 
required.
13 -  Install sheet metal screws (provided) to seal extra 
two holes in cabinet not used with side vent clamps.
 IMPORTANT
Side vent sealing plates and side vent sealing gaskets 
must be used when converting to right side venting. 
Failure to use gaskets and plates may lead to improper 
operation of unit.
Exhaust/Air
Intake Connections
Pipe Clamp
Hose Clamp
FIGURE 13 
Sheet Metal
Patch Plate
FIGURE 14