SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP99DF070XV36B SLP99DF090XV36C SLP99DF090XV48C
1
AFUE 97.5% 97.5% 97.5%
Maximum Input - Btuh 66,000 88,000 88,000
Output - Btuh 64,000 84,000 85,000
Temperature rise range - °F 50 - 80 60 - 90 50 - 80
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
Minimum Input - Btuh 23,000 31,000 31,000
Output - Btuh 22,000 30,000 30,000
Temperature rise range - °F 35 - 65 35 - 65 35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5 0.5 / 1.5 0.5 / 1.5
High static - in. w.g. 0.8 0.8 0.8
Connections
in.
Intake / ² Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4
with furnished 90° street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt
with eld supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nominal diameter x width - in. 10 x 9 10 x 9 11 x 11
Motor output - hp 1/2 1/2 3/4
Tons of add-on cooling 2 - 3 2 - 3 3 - 4
Air Volume Range - cfm 410 - 1365 465 - 1385 545 - 1745
Electrical Data Voltage (Maximum Amps) 120 volts - 60 Hertz - 1 phase
Blower motor full load amps 7.7 7.7 10.1
Maximum overcurrent protection 15 15 15
Shipping Data lbs. - 1 package 141 156 166
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization E󰀩ciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
2
2 in. Rubber Flue Coupling is furnished for exhaust pipe connection to unit.
SPECIFICATIONS
Gas
Heating
Performance
Model No. SLP99DF090XV60C SLP99DF110XV60C
1
AFUE 97.5% 97.5%
Maximum Input - Btuh 88,000 110,000
Output - Btuh 85,000 107,000
Temperature rise range - °F 50 - 80 50 - 80
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0
Minimum Input - Btuh 31,000 39,000
Output - Btuh 30,000 38,000
Temperature rise range - °F 35 - 65 35 - 65
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
0.5 / 1.5 0.5 / 1.5
High static - in. w.g. 0.8 0.8
Connections
in.
Intake / ² Exhaust Pipe (PVC) 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4
with furnished 90° street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt
with eld supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nominal diameter x width - in. 11 x 11 11 x 11
Motor output - hp 1 1
Tons of add-on cooling 3.5 - 5 3.5 - 5
Air Volume Range - cfm 467 - 2130 575 - 2180
Electrical Data Voltage (Maximum Amps) 120 volts - 60 Hertz - 1 phase
Blower motor full load amps 12.8 12.8
Maximum overcurrent protection 20 20
Shipping Data lbs. - 1 package 166 175
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization E󰀩ciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
2
2 in. Rubber Flue Coupling is furnished for exhaust pipe connection to unit.

Other manuals for Lennox SLP99DFV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox SLP99DFV Series and is the answer not in the manual?

Lennox SLP99DFV Series Specifications

General IconGeneral
BrandLennox
ModelSLP99DFV Series
CategoryFurnace
LanguageEnglish

Related product manuals