SPB − 3 to 5 Ton R−410A Heat Pump Outdoor Units / Page 10
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh Efficiency Total Watts COP
High
Low
HSPF
Hi
h Low Hi
h Low
Indoor Unit Model No.
Device
oo
ng
Temp.
Heating
Temp.
Heating
SEER EER IV V
oo
Heat
Heat
Heat
Heat
SPB036H4 3 TON
Air Handlers Air Handlers
34,600 33,000 20,000 14.70 11.20 8.00 6.70 3080 2980 2550 3.24 2.30
3
CBX32M−030 (Multi−Position) Factory TXV
34,800 33,000 19,900 15.00 11.20 8.00 6.70 3065 2975 2540 3.26 2.30
3
CB30U−31 (Up−Flow)
2
49L24
34,800 33,600 20,400 13.80 10.80 7.95 6.90 3200 3045 2640 3.24 2.26
3
CB29M−46 (Multi−Position) Factory TXV
34,800 33,600 20,600 13.80 10.50 7.70 6.75 3285 3210 2740 3.06 2.20
3
CB29M−51 (Multi−Position) Factory TXV
35,200 33,000 19,900 15.50 11.50 8.00 7.00 3055 2900 2495 3.34 2.34
4
CBX32MV−024/030 (Multi−Position) Factory TXV
35,200 33,200 20,000 14.70 11.20 8.00 7.00 3105 2950 2550 3.30 2.30
3
CBX32M−036 (Multi−Position) Factory TXV
35,400 33,400 20,200 14.50 11.20 8.00 6.70 3125 2950 2570 3.32 2.30
3
CB30U−41/46 (Up−Flow)
2
49L24
35,600 33,200 19,900 16.00 11.70 8.20 7.00 3045 2865 2480 3.40 2.34
4,5
CBX32MV−036 (Multi−Position) Factory TXV
35,600 33,000 19,700 15.70 11.70 8.20 7.00 3000 2835 2440 3.42 2.36
4
CBX27UH−036 (Up−Flow/Horizontal)
2
49L24
35,600 33,600 20,400 14.70 11.20 8.20 7.20 3110 2895 2470 3.40 2.42 CBX26UH−030 (Up−Flow / Horizontal) Factory TXV
36,000 33,600 20,400 14.50 11.50 8.20 7.20 3110 2865 2455 3.44 2.44 CBX26UH−036 (Up−Flow / Horizontal) Factory TXV
36,800 32,800 19,700 16.20 12.20 8.20 7.20 2970 2805 2385 3.42 2.42
4
CBX27UH−042 (Up−Flow/Horizontal)
2
49L24
Up−Flow Indoor Coils Up−Flow Coils
35,200 33,800 20,600 14.00 11.00 8.00 7.00 3190 2995 2565 3.30 2.36
3
CX34−38A/B−6F Factory TXV
Up−Flow Indoor Coils + Furnaces Up−Flow Coils + Furnaces
35,600 33,600 20,400 15.20 11.20 8.20 7.00 3125 2915 2490 3.38 2.40 CX34−38A−6F
4
G60UHV−36A−070 Factory TXV
35,600 33,600 20,400 15.20 11.20 8.20 7.00 3145 2930 2505 3.36 2.38 CX34−38B−6F
4
G61MPV−36B−045 Factory TXV
35,600 33,400 20,200 15.20 11.50 8.20 7.00 3100 2910 2475 3.36 2.38 CX34−38B−6F
4
G61MPV−36B−070 Factory TXV
35,800 33,200 20,000 15.70 11.70 8.20 7.20 3040 2830 2405 3.44 2.44 CX34−38B−6F
4
G60UHV−36B−090 Factory TXV
36,200 32,200 19,500 16.00 11.70 7.70 6.70 3035 3075 2580 3.06 2.22 C33−44C
4
G61MPV−36C−090
2
49L24
36,400 32,000 19,400 16.00 12.00 7.70 6.70 3000 3080 2560 3.04 2.22 CX34−43C−6F
4
G61MPV−36C−090
2
49L24
36,400 32,200 19,500 16.00 11.70 7.70 6.70 3040 3095 2585 3.04 2.20 CX34−43B−6F
4
G60UHV−36B−090
2
49L24
Down−Flow Indoor Coils Down−Flow Coils
34,800 33,400 20,400 13.70 10.90 7.70 6.70 3190 3065 2610 3.20 2.28
3
CR33−48B/C−F
2
49L24
35,800 34,000 20,600 14.20 11.20 8.20 7.00 3195 2950 2555 3.38 2.36
3
CR33−50/60C−F
2
49L24
Down−Flow Indoor Coils + Furnaces Down−Flow Coils + Furnaces
35,200 33,200 20,200 15.20 11.20 8.00 7.00 3100 2980 2520 3.26 2.34 CR33−48B−F
4
G61MPV−36B−070
2
49L24
35,200 33,400 20,200 15.20 11.20 8.00 7.00 3140 2995 2550 3.26 2.32 CR33−48B−F
4
G61MPV−36B−045
2
49L24
35,400 32,800 19,800 15.70 11.70 8.00 7.00 3000 2885 2425 3.34 2.40 CR33−48C−F
4
G61MPV−36C−090
2
49L24
35,400 32,800 19,900 15.50 11.50 8.00 7.00 3015 2890 2435 3.32 2.40 CR33−48B−F
4
G60DFV−36B−090
2
49L24
36,400 33,200 20,000 16.00 12.00 8.50 7.20 3005 2765 2370 3.52 2.48 CR33−50/60C−F
4
G61MPV−36C−090
2
49L24
Horizontal Indoor Coils Horizontal Coils
34,800 33,600 20,400 13.70 10.95 7.70 6.70 3185 3045 2595 3.24 2.30
3
CH23−51
2
49L24
35,200 33,800 20,600 14.00 11.00 8.00 7.00 3190 2980 2555 3.32 2.36
3
CH23−65
2
49L24
Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces
35,800 32,200 19,500 15.70 11.70 7.70 6.70 3035 3105 2590 3.04 2.20 CH33−42B−2F
4
G60UHV−36B−090
2
49L24
36,200 32,000 19,400 16.00 12.00 7.70 6.70 3000 3085 2565 3.04 2.22 CH33−48C−2F
4
G61MPV−36C−090
2
49L24
36,200 32,200 19,500 16.00 11.70 7.70 6.70 3040 3075 2585 3.06 2.20 CH33−44/48B−2F
4
G60UHV−36B−090
2
49L24
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings − 95_F outdoor air temperature and 80_F db/67_F wb entering indoor coil air.
High Temperature Heating Ratings − 47_F db/43_F wb outdoor air temperature and 70_F db entering indoor coil air.
Low Temperature Heating Ratings − 17_F db/15_F wb outdoor air temperature and 70_F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.