DiagnosticErrorCodeFRU/Action
000-250-XXXBIOSAPMfailure1.Flashthesystem.See“Flashupdateprocedures”
onpage375
2.Systemboard
000-270-XXXBIOSACPIfailure1.Flashthesystem.See“Flashupdateprocedures”
onpage375
2.Systemboard
001-000-XXXSystemTestPassed
Noaction
001-00X-XXXSystemErrorSystemboard
001-01X-XXXSystemErrorSystemboard
001-024-XXXSystemAddressingtestfailureSystemboard
001-025-XXXSystemChecksumValueerror1.Flashthesystem.See“Flashupdateprocedures”
onpage375
2.Systemboard
001-026-XXXSystemFLASHdataerror1.Flashthesystem.See“Flashupdateprocedures”
onpage375
2.Systemboard
001-027-XXXSystemConguration/Setuperror1.RunSetup
2.Flashthesystem.See“Flashupdateprocedures”on
page375
3.Systemboard
001-032-XXXSystemDeviceControllerfailureSystemboard
001-034-XXXSystemDeviceBufferAllocationfailure
1.Rebootthesystem
2.Flashthesystem.See“Flashupdateprocedures”on
page375
3.Runmemorytest
4.Systemboard
001-035-XXXSystemDeviceResetconditiondetectedSystemboard
001-036-XXXSystemRegistererrorSystemboard
001-038-XXXSystemExtensionfailure
1.Adaptercard
2.Systemboard
001-039-XXXSystemDMIdatastructureerror1.Flashthesystem.See“Flashupdateprocedures”
onpage375
2.Systemboard
001-040-XXXSystemIRQfailure1.Power-off/onsystemandre-test
2.Systemboard
001-041-XXXSystemDMAfailure1.Power-off/onsystemandre-test
2.Systemboard
001-195-XXXSystemTestabortedbyuser
InformationonlyRe-startthetest,ifnecessary
001-196-XXXSystemtesthalt,errorthresholdexceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
54HardwareMaintenanceManual