Dependingonthespecifictype,thePCIExpresssolid-statedrivemightlookdifferentfromtheillustrations
inthistopic.
ToreplacethePCIExpresssolid-statedrive,dothefollowing:
1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectall
powercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedtotheserver.
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.
3.Removetheservercover.See“Removingtheservercover”onpage75.
4.Removethecoolingshroud.See“Removingthecoolingshroud”onpage79.
5.Removetherisercardassembly1andlayitupsidedownonaflat,clean,andstatic-protectivesurface.
See“Replacingtherisercardassembly1”onpage160.
6.GraspthePCIExpresssolid-statedrivebyitsedgesandcarefullypullitoutoftheslotontheriser
cardassembly1.
Note:ThePCIExpresssolid-statedrivemightfittightlyintotheslot.Ifnecessary,alternatemoving
eachsideofthePCIExpresssolid-statedriveasmallandequalamountuntilitiscompletelyremoved
fromtheslot.
Figure104.RemovingthePCIExpresssolid-statedrive
7.Touchthestatic-protectivepackagethatcontainsthenewPCIExpresssolid-statedrivetoany
unpaintedsurfaceontheoutsideoftheserver.Then,takethenewPCIExpresssolid-statedriveout
ofthepackage.
Note:CarefullyhandlethePCIExpresssolid-statedrivebyitsedges.
146ThinkServerRD340UserGuideandHardwareMaintenanceManual