4.Removethecoolingshroud.See“Removingthecoolingshroud”onpage73.
5.Removeanypartsanddisconnectanycablesthatmightimpedeyouroperation.
6.LocatetheM.2storagemoduleanddisconnectthecables.See“Servercomponents”onpage26.
7.Pressthetworeleasetabs1andlifttheM.2storagemoduleoutofthechassis.
Note:CarefullyhandletheM.2storagemodulebyitsedges.
Figure66.RemovingtheM.2storagemodule
8.RemovethescrewthatsecurestheM.2storagedrive.Then,removetheM.2storagedrive.
Figure67.RemovingtheM.2storagedrive
9.IfyouareinstructedtoreturntheoldM.2storagemodule,followallpackaginginstructionsanduseany
packagingmaterialsthataresuppliedtoyouforshipping.
Whattodonext:
•Toworkwithanotherpieceofhardware,gototheappropriatesection.
•Tocompletetheremovalprocedure,goto“Completingthepartsreplacement”onpage175.
114ThinkServerTD350UserGuideandHardwareMaintenanceManual