Notes:
Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.
Dependingonthemodel,thefollowingdevicesmightbeinstalledintheopticaldrivebays:
Opticaldrive
Flexmodulewithaslimopticaldriveinstalled
Useanydocumentationthatcomeswiththeopticaldriveandfollowthoseinstructionsinadditionto
theinstructionsinthistopic.
Installingorreplacinganopticaldrive
Note:Thefollowinginstructionsalsoapplytoa5.25-inchflexmodule(availableonsomemodels).
Toinstallorreplaceanopticaldrive,dothefollowing:
1.Removeallexternalmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,
disconnectallpowercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedto
theserver.
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.
3.Removetheservercover.See“Systemboardcomponents”onpage44.
4.Locatetheoptical-drivebays.See“Frontviewoftheserver”onpage18.Readtheopticaldrive
installationrulesin“Installingorreplacingadeviceinanopticaldrivebay”onpage117.
5.Dependingonwhetheryouareinstallingorreplacinganopticaldrive,dooneofthefollowing:
Ifyouareinstallingasecondaryopticaldriveintotheupperoptical-drivebay,insertafingerintothe
holeasshowntopushtheprotectiveshielduntilitisprojectedfromthefrontofthechassis.Then,
holdtheprotectiveshieldfromthefrontandcompletelyslideitoutofthechassis.
Figure70.Removingtheprotectiveshieldoftheoptical-drivebay
118ThinkServerTD350UserGuideandHardwareMaintenanceManual